INSTALLATION PROCEDURE
[B]
9. Remove the right cover [A] of the copier (2 screws) and the plastic cap
[B]. Reinstall the right cover passing the interface harness [C] (3
connectors and 1 ground wire) through the lower hole of the right cover.
10. Fix the upper and lower stays [D] (5 screws) to enable fixing of the
diagonal transport unit.
[C]
23
[A]
6 March 1992
[D]