Christie CP2000-X User Manual page 55

Hide thumbs Also See for CP2000-X:
Table of Contents

Advertisement

CP2000-X User Manual
020-100031-01 Rev . 1 (03-2009)
Table 3.1. Summary of Status:System Menu
STATUS:SYSTEM MENU ENTRIES
Source
Projector Input
Signal
Cine-IPM (not applicable for CP2000 projectors)
Power
Input and Channel
Signal
Standby
OSD
Environment
Projector Hours
Total Lamp Hours
Lamp
Current
Voltage
Power
Footlamberts
LiteLOC
Interlocks
Lamp Fan
(rear of projector)
Extractor Fan
(for ducting to outside
world)
Lamp Door
(louvered lamp door)
High Current
Tamper
(projector lid)
Temperatures (°C or °F) *
Card Cage
DMD – Blue
DMD – Red
Integrator
Prism
SSM
Fan Speeds *
Fan #1 ("Intake #1")
Fan #2 ("Intake #2")
Card cage
LAD
Built-in Self-Test
NOTE: If any of the following indicators are "red", service may be needed.
General
System
Power-up Self Test
Security Lock Integrity
I
2
C
Interface Board
Diagnostics Performed
ARM
FPGA Load
FPGA Code Valid
FPGA Initialize
FPGA No-Load Jumper
FPGA Done
FPGA Register Read/Write
UART 0
UART 1
I
2
C
Ethernet
Synchronous Serial Port
File System
GPI Macro
A/D Macro
Formatter Board (a.k.a. Formatter Interface
Board)
BASIC OPERATION
Source connection (location) of current signal
Vert. Freq.
On/off
Source connection (location) and channel#
Hor. & Vert. Freq. of current source
On/off (NOTE: lamp remains on regardless)
On/off screen display of Cine-IPM menus
#Hours projector has been powered up and
communicating with the TPC
#Hours logged for all lamps ever installed
#Hours logged on current lamp
Lamp current (#amps)
Lamp voltage (#volts)
Lamp power (#watts)
Footlamberts (interpolated from min/max calibration)
On/Off/At Maximum Power
Critical safety and/or operation monitoring
OK/Failure. Failure also triggers an alarm window
OK/Failure. Failure also triggers an alarm window
OK/Failure. Failure also triggers an alarm window
OK/Failure. Failure also triggers an alarm window
OK/Failure. Failure triggers an alarm window and
stops CineLink
®
2 -encrypted cinema processing.
Critical internal temperatures in °C or °F
55-69°C=warning
≥70°C=critical
50-54°C=warning
≥55°C=critical
50-54°C=warning
≥55°C=critical
95-104°C=warning
≥105°C=critical
70-74°C=warning
≥75°C=critical
55-59°C=warning
≥60°C=critical
Speed (RPMs) of 4 internal cooling fans
RPMs of 1
st
primary fan (exhaust side of proj.)
RPMs of 2
nd
primary fan (exhaust side of proj.)
RPMs of electronics card cage fan
RPMs of laminar airflow device for DMDs
3-13