BASIC OPERATION
3-24
ADVANCED / PREFERENCES MENU:
access to all test patterns as well as certain system parameters. See Table 3.7 for a
complete description.
Figure 3.12. Advanced: Preferences Menu Functions
Table 3.6. Summary of Advanced Preferences Menu Functions
ADVANCED / PREFERENCES MENU OPTIONS
Test Patterns
Full Screen
Alarm Triggers
Lamp Limit
Expiry Message
Language
System Calendar & Clock
* Screen Saver
* NOTE: To use a unique screen saver, a user-defined .bmp must be downloaded to the TPC, replacing the default.
ADVANCED / LAMP MENU:
controls for optimizing lamp alignment (LampLOC), maintaining a specific light
output over time (LiteLOC), or setting a precise power level for the lamp. Two read-
only areas display related lamp performance details—the side bar graph represents
the current light output and, if LiteLOC is enabled, a heavy line shows the chosen
LiteLOC setting. In addition, the New Lamp button activates a window for entering
the serial number of a newly installed lamp. This button is also available with an
As shown below, the Preferences menu provides
Display an RGB 12-bit test pattern, or turn patterns off. Always turn OFF
to resume normal operation.
Enter a checkmark to display test patterns in full 2048 x 1080
resolution. Clear the checkbox to work with cropping controls for
screen size and shape as desired. Note changes are temporary, i.e.
applied for the current test pattern only. This control is not used for
sources.
Choose which conditions you want to trigger an Alarm Window (in
addition to interlocks and problems with the SSM, I
are all permanent triggers). It is recommended that all triggers remain
enabled during normal operation. Disable only in an rare emergencies
when the alarm appears to be malfunctioning without real errors.
Enter the #hours (0-5000) that are expected for this lamp, typically no
more than the number of hours covered under warranty.
Enter a checkmark so that a Lamp Expiry Message will appear on the
TPC when the lamp reaches its defined Lamp Limit.
Choose English or Chinese TPC menu text for next re-boot.
Reset the system date/time as desired. Select the desired component
(date/hour/minute/second) and adjust. Save (restart) with "Set" button.
Enable/disable a TPC screen saver, and set its start-up delay.
As shown in Figure 3.13, the Lamp menu provides