020-100031-01 Rev. 1 (03-3009)
Function Code / Examples
(LPI 12345)
(LPI?)
(LPI?s101)
(LP1!12345)
Lamp Limit (LPL)
(LPL 750)
(LPL?)
(LPL!750)
LampLOC Module (LLM)
(LLM000 000 0158)
Lamp Message Enable (LME)
(LME 0)
(LME 1)
Lamp Mode (LPM)
(LPM 2)
(LPM?)
(LPM! 3)
Lamp Per Button (LPB)
(LPB O)
(LPB?)
(LPB! 1)
Lamp Power (LPP)
(LPP 2000)
(LPP?)
(LPP!2000)
Measured Color Gamut (MCG)
(MCG "OnSite")
(MCG?)
(MCG! OnSite)
Ping (PNG)
(PNG?)
(PNG! 032 001 002)
Power (PWR)
(PWR 0)
(PWR 1)
(PWR! 000)
(PWR! 001)
Processing Mode (PRM)
(PRM 0)
Description and Parameters
The light output level chosen for LiteLOC. Same intensity
for every channel requires LPB (Lamp Per Button) set to
"OFF".
NOTE: Specify desired channel with "S". If no "S" parameter is included,
the LPI setting will apply to the current channel when the "Lamp Per
Channel" checkbox is enabled, and to all channels when the checkbox is
cleared.
What is the current LiteLOC setting for this channel?
What is the LiteLOC setting for Channel #1?
The current LiteLOC setting is 12345
The #hours that a lamp can be used before a warning
message appears. Range=0-5000 hours.
P1 = Type of motor movement
0=move to a specific new position
1=calibrate motors
2=Do AUTO lamp alignment (LampLOC)
P2 = Which motor...x(0), y(1), or z(2)
P3 = Destination / new motor position (-200 up to +200)
0 = No lamp message will appear when lamp limit expires
1 = Lamp message will appear when lamp limit expires
2 = Constant power
3 = Constant light intensity
NOTE: Specify desired channel with "S". If no "S" parameter is included,
the LPM setting will apply to the current channel when the "Lamp Per
Channel" checkbox is enabled, and to all channels when the checkbox is
cleared.
0 = Off; Lamp settings will be the same for all channels.
1 = On; Lamp settings will vary according to channel.
NOTE: This setting determines whether lamp mode, power and intensity
are the SAME for every channel (i.e., global) or DIFFERENT for each.
Specific power setting (#watts) for driving the lamp.
Range = depends on the installed lamp
NOTE: Specify desired channel with "S". If no "S" parameter is included,
the LPP setting will apply to the current channel when the "Lamp Per
Channel" checkbox is enabled, and to all channels when the checkbox is
cleared.
Use OnSite MCGD as the reference point for color proc.
What MCGD is currently in use?
Reply indicating the OnSite MCGD is in use
Request for projector type and current s/w version
Reply indicating cinema projector present (32), and its
current version of software is v1.2
P1 = 32 (always—indicates a cinema projector)
P2 = Major version 0-99
P3 = Minor version 0-99
Turn the projector off or on (0=off, 1=on). Examples:
Turn the projector (lamp) off
Turn the projector (lamp) on
The projector (lamp) is off
The projector (lamp) is on
Current processing of incoming source data, where 0=
ASCII MESSAGES
(see P2 and P3)
B-3