Audible Noise; Operating Environment - Christie CP2000-X User Manual

Hide thumbs Also See for CP2000-X:
Table of Contents

Advertisement

Lamps 
Audible Noise 
Safety 
EMC Emissions 
EMC Immunity 
Operating Environment 
CP2000-X User Manual
020-100031-01 Rev . 1 (03-2009)
7 kW 3-Phase Ballast
Nominal Voltage per 
Nominal Operating Range
Line Frequency
Inrush current (max.)
note: excluding lamp
Current consumption per phase (max.) @ 6.6
kW
Power consumption (max.)
Current rating (continuous) of 3-phase AC input
at breaker
Breaker rating
BALLAST OUTPUT TO PROJECTION HEAD
Operating voltage range
Start-up voltage (open current)
Operating current range
Ripple
Control ports
CXL/CDXL Lamps
(kW)
CDXL-20
(2.0)
CXL/CDXL-30 (3.0)
CXL/CDXL-45 (4.5)
CXL/CDXL-60 (6.0)
CDXL-60SD (7.0)
* NOTE: Current range shown includes "over-drive" of approximately 10% more than the original
lamp rating.
Type
Stand-by lamp power level for 4-6 kW
Stand-by lamp power level for 2-3 kW
Motorized adjustment of position
Recommended screen widths:
2.0 kW = 5 ft. max.
3.0 kW = 55 ft. max.
4.5 kW = 65 ft. max.
6.0 kW = 75 ft. max.
All screen sizes approximate and assuming 1.5 screen gain if <70 ft., and 1.8 screen gain if >70 ft.
70 dBA maximum (NOTE: Does not include customer-supplied external extractor
fan.)
• UL 60950-1 and CAN/CSA C22.2. No. 60950-1-03 1
• IEC 60950-1:200
FCC CFR47, Part 15, Subpart B, Class A — Unintentional Radiation
CISPR 22: 2003 +A1:2004 / EN55022: 1998 +A2:2003, Class A —
Information Technology Equipment
CISPR 24:1997 / EN55024:1998 +A1:2001 +A2:2003 EMC Requirements –
Information Technology Equipment
(38-814001-01)
• 208 VAC (N. America / Japan)
• 400 VAC (Europe)
• 200-230 ± 10% (N. America / Japan)
• 380-415 ± 10% (Europe)
50-60 Hz nominal
<50 A
• 28 A @ 208 VAC (N. America / Japan)
• 16 A @ 400 VAC (Europe)
• 14.4 kVA (9.1 kW), all regions
30 A, all regions
50 A
18-46 VDC
125-155 VDC
50-180 A
1% max @ 25°C
See Control Port and Interlock Port on
previous page
Current Range
(amps)
66-88
82-120
112-150
126-170
Xenolite
50% of lamp's maximum current rating
75% of lamp's maximum current rating
3-axis, 0.25" range for each
SPECIFICATIONS
Lamp Life (warranty hrs.)
1200 full / 2400 pro-rated
720 full / 1440 pro-rated
60 full / 900 pro-rated
50 full / 500 pro-rated
®
st
edition, bi-national
8-3