Using the Custom 3D Control Menu
NOTES: 1) 3D functionality requires an EFIB (Enhanced Formatter Interface Board
as well as a Series 1 Interface board. Consult the About menu. 2) Connect your 3D
HD-SDI source signals to cinema A and B ports (dual). 3) Assumes software v8.0 or
higher.
Custom 3D Control menu options are summarized in Figure 3.10 and Table 3.5.
Enable the 3D checkbox in order to 1) enable 3D display and adjustment parameters
2) automatically configure the Input and Data Format (on the Custom Page-1 menu).
For full 3D application notes, including a step-by-step tutorial for use, see section
3.9, Working with 3D.
Figure 3.10. Custom:3D Control Menu
Table 3.5. Summary of Custom 3D Control Menu Functions
CUSTOM: 3D CONTROL MENU OPTIONS (SUMMARY)
Enable 3D (checkbox)
Enable 3D Test Pattern
3D Input Reference
Input Frame Reference
L/R Output Polarity
Frame Rate N:M
Input GPI
Display GPI
Output GPO
Dark Time Adj
Output Delay (Time)
Activate 3D controls and auto-set Input to 292 Dual Input and Data
Format to Unpacked 4:2:2 in the Custom Page-1
For confirming proper Sync Output setting (i.e., which GPO is connected to
your 3D peripherals such as emitters, glasses, etc.
Defines how 3D stereo sync input is supplied (currently ports A and B
only). See "NOTES" below.
Define frame order (L-R or R-L) required for 3D perspective. Correct
setting ensures smooth motions, and depends on the original source
mastering. See "NOTES" below.
Keeps 3D stereo sync output the same as input (true), or reversed
(inverted). See "NOTES" below.
Ratio of total #frames displayed to #frames forming complete data.
Increase to reduce flicker in displays < 96 Hz. Max. recommended
setting for 2048 x 1080 displays = 5:2. Can be higher in smaller
displays, or decreased if incoming signal is already high enough to
prevent flicker. See "NOTES" below.
Select "None" when 3D stereo sync input is part of source signal at
ports A and B. Use GPI 1-7 if sync input is supplied to GPIO port. (Must
match L/R Input Reference setting.)
Always "None" unless 3D stereo sync input is at GPIO connector. (Must
match L/R Display Reference setting.)
Define your GPO sync output for 3D device (glasses or z-screen
polarization), using to 1-7 depending on wiring.
Create a blank time interval between L/R frames to allow for glasses
on/off. Helps synchronize the output to the viewing.
Offset (in μ) 3D stereo sync output in relation to dark time interval.
Positive offset = delay, negative offset = start early. See "NOTES"
below.