STEP 14 
STEP 15 
STEP 16 
Filter Replacement 
Procedure
BEFORE YOU BEGIN 
STEPS 1-2 
STEPS 3-4 
STEPS 5-6 
CP2000-X User Manual
020-100031-01 Rev . 1 (03-2009)
Do not attempt to ignite the lamp until its type (kW)
Turn the lamp ON
Press and hold the lamp button on the TPC Main menu.
Adjust lamp position
Using the TPC, adjust the lamp position within the projector as described in 3.7,
Working With the Lamp. This ensures maximum performance, with the lamp (bulb)
well centered with the reflector and distanced correctly from the rest of the
illumination system.
Record the serial number of the new lamp
In the Advanced: Lamp menu, select "New Lamp".
1.
In the Lamp History submenu, enter the serial number in the text box.
2.
Save to record the number and to reset the lamp timer. The timer will now begin
3.
to log time for the new lamp.
Replace the air filter whenever the lamp module is replaced, or more frequently if
operating the projector in a dusty or dirty environment. Check monthly in all cases.
The filter is located on the operator's side of the projection head, near the front.
See Figure 6.4.
Power down and disconnect from AC
Follow steps 1-3 from the Lamp Replacement Procedure, above.
Open/remove filter door
Loosen 2 corner screws (flat screwdriver), and lift off door.
Replace air filter
Slide the old filter up and discard. Insert the new air filter, following the labeling for
proper inside/outside orientation. Slide all the way down into its slot.
Use only Christie filters. Never operate
the projector without the filter installed.
Close/replace filter door
With the filter in place, insert the bottom tabs of the filter door into the corresponding
slots, close the filter door, and secure with 2 screws.