ASCII MESSAGES
B-6
Table B.2. Error Messages
Error Code (P1)
Type of Error (P2)
001
"System Error: -----"
002
"System Warning: -----"
003
"Invalid parameter—"
004
"Too many parameters"
005
"Too few parameters"
006
"Source does not exist"
007
"Could not be
executed"
008
"Checksum error"
009
"Unknown request"
010
"Communication error"
Additional Parameters for "001" System Errors and "002"System
Warnings
"System Error" and "System Warning" error messages include two additional
parameters (P3 and P4), which further describe the error. P3 indicates what
component or system is involved (such as interlocks, fans, temperature, SSM
communication, or a lamp failure) and P4 relays the specific condition detected at the
suspect component, such an over-temperature reading or a slow fan speed reading—
note these values indicate temperature or fan speed only. See Table B3, B4, and B.5
below.
When a system error is resolved and is no longer present, another message reports
this by replacing the first digit in the original P3 error code with a "1".
Table B.3. P3 Codes for "001" System Error Messages"
Component Code (P3)
0001
0002
0003
0004
0005
0008
0009
000A
000B
000C
0010
0011
0012
0013
0014
0015
0016
0021
0022
0023
0024
0030
System critical error.
System error.
Invalid parameter number.
Message requires fewer parameters
Message requires more parameters
The source# is wrong
Current content prevented the command
from executing.
The checksum is incorrect.
Message code undefined. If the message
sent as a command it is ignored and no
error is returned.
Error receiving serial data on one of the RS-
232 ports.
Interlock, Lamp Fan
Interlock, Extractor
(exit duct to outside world)
Interlock, Lamp Door
Interlock, Auxiliary
Interlock, Tamper
Fan, Intake 1
(non-operator's side of projection head)
Fan, Intake 2
(non-operator's side of projection head)
Fan, Card Cage
Fan, LAD
(laminar airflow device near light engine)
Fan, Ballast
Temperature, Prism
Temperature, DMD Red
Temperature, DMD Blue
Temperature, Integrator
Temperature, SSM
(System Supervisor Module)
Temperature, Card Cage
Temperature, Ballast
Lamp, Failed to Ignite
Lamp, Ignition Failed on 2
nd
Lamp Off (detected by no light or current)
Light Sensor Reading Failure
SSM, Communication Failure
Meaning
Component
Strike
(System Supervisor Module)
CP2000-X User Manual
020-100031-01 Rev. 1 (03-2009)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents