INSTALLATION & SETUP
2-20
Direct the exhaust, as necessary, to keep ambient air temperature within operating
spec (see Section 6, Specifications). If the projector is used for extended periods,
particularly in a confined space, routing to the outside of the building may be
required. In all cases, maintain at least 600 CFM at the projector's top exit port:
Table 2.4. Airflow Requirements
Lamp (kW)
2.0
3.0
4.5
6.0
Follow the installation guidelines provided below; securing all
INSTALLATION:
components in the order that best suits your site and installation requirements.
Do not operate the projector without the Christie
INSTALL DUCT ON PROJECTOR:
Figure 2.24 below. Align either the 6-
inch or 6-foot duct at the projector's
top exit port, twisting to secure "flaps"
over projector pins. Confirm that 1)
there are no obstructions or kinks
within the ducting, 2) all air intake
areas of the projector are clear and
exposed, and 3) the vane switch at the
exit duct moves freely.
Minimum Exhaust Airflow Rate
450 ft
3
/min.
450 ft
3
/min.
3
600 ft
/min.
600 ft
3
/min.
WARNING
Extractor components installed.
See
Figure 2.24. Securing Duct to
Projector
CP2000-X User Manual
020-100031-01 Rev. 1 (03-2009)