Remote Control
Command
Arguments
Parameter
(Instruction
for Command
Type
Code and
or Response
Qualifier)
Retrieve next 5
N/A
80 bytes
unread Stored
Events
Clear All
CAE=
None
Stored Events
Initialize
IEP=
None
Events Pointer
Rx Eb/No
N/A
4 bytes
Description of Arguments
to Query
Query only.
Unit returns the oldest 5 Stored Events which have not yet been
read over the remote control. Reply format: {CR}Sub-
body{CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Sub-body,
where Sub-body= ABCddmmyyhhmmss,
A being the fault/clear indicator.
F=Fault
C=Clear
I=Info
B being the fault type where:
1=Unit
2=Rx Traffic
3=Tx Traffic
4=Power on/off, or log cleared
C is Fault Code numbers, as in FLT? or Info Code, which is:
00=Power Off
01=Power On
02=Log Cleared
03=Global Config Change
04=Redundancy Config Change
If there are less than 5 events to be retrieved, the remaining
positions are padded with zeros.
If there are no new events, the response is RNE*.
Command only.
Forces the software to clear the software events log.
Note: This command takes no arguments
Example: CAE=
Command only.
Resets internal pointer to allow RNE? queries to start at the
beginning of the stored events log.
Query only.
Unit returns the value of Eb/No, between 0 and 16 dB,
resolution 0.1 dB.
Returns 99.9 if demod is unlocked.
Example EBN=12.3 (which is Eb/No = 12.3 dB)
For values greater than 16.0 dB, the reply will be: EBN=+016
Response to
Command
N/A
CAE=
CAE?
CAE*
CAE#
IEP=
IEP#
N/A
11–21
Revision 5
MN/CDM700.IOM
Query
(Instruction
Response to Query
Code and
Qualifier)
RNE?
RNE={CR}ABCCddmmy
yhhmmss{CR}ABCCddm
myyhhmmss{CR}ABCCd
dmmyyhhmmss{CR}AB
CCddmmyyhhmmss
{CR}ABCCddmmyyhhm
mss
N/A
N/A
N/A
N/A
EBN?
EBN=xxxx