Description
Use source port to configure the source port of probe packets.
Use undo source port to remove the configured port number.
By default, no source port number is configured.
Examples
# Configure port 8000 as the source port of probe packets in the UDP echo test group.
<Sysname> system-view
[Sysname] nqa entry admin test
[Sysname-nqa-admin-test] type udp-echo
[Sysname-nqa-admin-test-udp-echo] source port 8000

statistics hold-time

Syntax
statistics hold-time hold-time
undo statistics hold-time
View
DLSw, DNS, FTP, HTTP, ICMP echo, SNMP, TCP, UDP echo, UDP jitter, voice operation view
Default level
2: System level
Parameters
hold-time: Specifies the hold time of a statistics group in minutes, in the range of 1 to 1440.
Description
Use statistics hold-time to configure the hold time of statistics groups for a test group. A statistics group
is deleted when its hold time expires.
Use undo statistics hold-time to restore the default.
By default, the hold time of a statistics group is 120 minutes.
This command is not supported by DHCP tests.
Examples
# Configure the hold time of a statistics group as 3 minutes.
<Sysname> system-view
[Sysname] nqa entry admin test
[Sysname-nqa-admin-test] type icmp-echo
[Sysname-nqa-admin-test-icmp-echo] statistics hold-time 3

statistics max-group

Syntax
statistics max-group number
undo statistics max-group