HP 6125G Command Reference Manual page 19

Network management and monitoring
Hide thumbs Also See for 6125G:
Table of Contents

Advertisement

Field
reference
stra
reach
poll
now
offset
delay
disper
[12345]
Total associations
# Display detailed information about all NTP sessions.
<Sysname> display ntp-service sessions verbose
clock source: 127.127.1.0
clock stratum: 3
clock status: configured, master, sane, valid
reference clock ID: 127.127.1.0
local mode: client, local poll: 6
peer mode: server, peer poll: 6
offset: 0.0000 ms,delay: 0.00 ms,
root delay: 0.00 ms, root disper: 10.00 ms
reach: 1, sync dist: 0.010, sync state: 2
precision: 2^18, version: 3, peer interface: InLoopBack0
Description
Reference clock ID of the clock source:
If the reference clock is the local clock, the value of this field is
related to the value of the stra field:
When the value of the stra field is 0 or 1, this field is LOCL.
When the stra field has another value, this field is the IP
address of the local clock.
If the reference clock is the clock of another device on the
network, the value of this field is the IP address of that device.
Stratum level of the clock source, which determines the clock
precision. The value ranges from 1 to 16. The clock precision
decreases from stratum 1 to stratum 16. A stratum 1 clock has the
highest precision, and a stratum 16 clock is not synchronized.
Reachability count of the clock source. A value of 0 indicates that
the clock source in unreachable.
Poll interval in seconds, namely, the maximum interval between
successive NTP messages.
Length of time from when the last NTP message was received or
when the local clock was last updated to the current time.
Time is in seconds by default. If the time length is greater than 2048
seconds, it is displayed in minutes; if greater than 300 minutes, in
hours; if greater than 96 hours, in days.
Offset of the system clock relative to the reference clock, in
milliseconds.
Roundtrip delay from the local device to the clock source, in
milliseconds.
Maximum error of the system clock relative to the reference source.
1—Clock source selected by the switch, namely, the current
reference source.
2—Stratum level of the clock source is less than or equal to 15.
3—This clock source has survived the clock selection algorithm.
4—This clock source is a candidate clock source.
5—This clock source was created by a configuration command.
Total number of associations.
disper: 0.02 ms