Reaction Trap - HP 6125G Command Reference Manual

Network management and monitoring
Hide thumbs Also See for 6125G:
Table of Contents

Advertisement

[Sysname-nqa-admin-test-udp-jitter] reaction 1 checked-element rtt threshold-type
average threshold-value 50 5 action-type trap-only
# Create reaction entry 2 for monitoring the round-trip time of UDP jitter probe packets. Set the upper
threshold to 50 milliseconds, and lower threshold to 5 milliseconds. Before the NQA test group starts, the
initial state of the reaction entry is invalid. After each test, the packet round-trip time is checked against
the threshold range. If the total number of threshold violations exceeds 100 (included), the state of the
entry is set to over-threshold. Otherwise, the state of the entry is set to below-threshold. Once the state of
the reaction entry changes, a trap message is generated and sent to the network management server.
<Sysname> system-view
[Sysname] nqa entry admin test
[Sysname-nqa-admin-test] type udp-jitter
[Sysname-nqa-admin-test-udp-jitter] reaction 1 checked-element rtt threshold-type
accumulate 100 threshold-value 50 5 action-type trap-only

reaction trap

Syntax
reaction
trap
cumulate-probe-failures }
undo reaction trap { probe-failure | test-complete | test-failure }
View
Any NQA operation view
Default level
2: System level
Parameters
probe-failure consecutive-probe-failures: Sends a trap to the network management server if the number
of consecutive probe failures in one test is greater than or equal to consecutive-probe-failures. The value
for consecutive-probe-failures is in the range of 1 to 15. During the test, the system counts the number of
consecutive probe failures after each probe operation, so multiple traps might be sent.
test-complete: Sends a trap to indicate that the test is completed.
test-failure cumulate-probe-failures: Sends a trap if the total probe failures in an test is greater than or
equal to cumulate-probe-failures. The value for cumulate-probe-failures is in the range of 1 to 15. The
system counts the total probe failures after the test completes, so one trap at most is sent.
Description
Use reaction trap to configure the sending of traps to the network management server under specified
conditions.
Use undo reaction trap to restore the default.
By default, no traps are sent to the network management server.
Only the reaction trap test-complete command is supported by voice tests.
Examples
# Configure the system to send a trap if consecutive probe failures in an ICMP echo test is greater than
or equal to 5.
<Sysname> system-view
{
probe-failure
consecutive-probe-failures
154
|
test-complete
|
test-failure

Advertisement

Table of Contents
loading

This manual is also suitable for:

6125 blade switch series