HP 1910 User Manual page 132

Hp 1910 gigabit ethernet switch series
Hide thumbs Also See for 1910:
Table of Contents

Advertisement

Figure 100 Configuring an event group
Figure 101 Displaying the index of a event entry
4.
Configure an alarm group to sample received bytes on GigabitEthernet 1/0/1. When the
received bytes exceed the rising or falling threshold, logging is enabled:
a.
Click the Alarm tab.
b.
Click Add.
The page in
Figure 102
c.
Select Number of Received Bytes from the Static Item list, select GigabitEthernet1/0/1 from the
Interface Name list, enter 10 in the Interval field, select Delta from the Simple Type list, enter
user1 in the Owner field, enter 1000 in the Rising Threshold field, select 1 from the Rising Event
list, enter 100 in the Falling Threshold field, select 1 from the Falling Event list, and click Apply.
appears.
119