How to Create Custom Vacuum Zones
minimum of 15 mm from the outside edges of the media. This optimizes the sealing effect
between the media and the table.
[59] Join the tape with no gaps
Note:
Make sure there are no gaps at any of the places where tapes join at a right angle. Also
make sure the gray custom tape does not overlap the black perimeter tape.
Carefully lift the overlay back to its original position and rest the edge on the Control
7.
side of the table in the vertical orientation.
Note:
Ensure that the alignment holes in the overlay are on the same side as the two alignment
pins on the flatbed.
Lower the upper end of the overlay slowly as you slide your hand inward to support the
8.
center to avoid bending until it is completely level with the flatbed.
Line up the two holes in the overlay with the two registration pins and square the overlay
9.
to the flatbed.
Completely cover all zones, close the bleed valve, turn on the vacuum and verify the closed
10.
system vacuum level is > 20 inches of Hg. Also verify that the time it takes for the vacuum
to establish is less than 4 seconds.