Fill the Coolant Reservoir

Illustration
[157] Fill Coolant Reservoir
Fill the Coolant Reservoir
Open the container of coolant fluid.
1.
Insert the syringe into the fluid and draw back the plunger until the syringe is almost full
2.
(leave a small amount of air so that you can expel it at the end to avoid fluid dripping
from the fill nozzle.
Wipe any excess fluid from the hose attached to the syringe (if the hose is wet it is difficult
3.
to perform the next step).
Insert the hose into the fill nozzle above the coolant level tube.
4.
Press on the syringe plunger to inject the fluid. Inject the entire contents of the syringe.
5.
Repeat, if necessary, until the coolant level is above the halfway point on the sight tube.
Note:
Do not overfill the coolant as this can cause temperature variations. If the coolant does
not flow into the fill nozzle the printer may have a defective nozzle and this will require
a service call.
Remove the hose and store the syringe and the coolant fluid container until it is needed
6.
again.