Removing A Ethernet Switch Module; Pull The Release Latch On The Ethernet Switch - Dell PowerConnect 5316M User Manual

Switch module
Hide thumbs Also See for PowerConnect 5316M:
Table of Contents

Advertisement

Removing a Ethernet Switch Module

CAUTION:
attached.
NOTE:
Neither the Server Modules, nor the Dell Modular Server Chassis needs to be powered down to
remove a Ethernet Switch Module.
NOTE:
By removing an Ethernet Switch Module, the connection to the network is broken.
NOTE:
The replacement Ethernet Switch Module or an end-cap (blank plug) must be installed within 1
minute of removing an Ethernet Switch Module or an end-cap (blank plug).
To remove a Ethernet Switch Module from Dell Modular Server Chassis perform the following:
1
Review and become familiar with the safety and handling guidelines specified under "Safety"
and "Handling Static Sensitive Devices."
2
Select the Ethernet Switch Module to remove. In this example, an Ethernet Switch Module is
being removed from Bay 1. For other modules and their positions see "Ethernet Controller
Enumeration."
3
Complete any Dell Modular Server Module tasks as specified in the Dell PowerEdge 1855
Systems User's Guide and Dell PowerEdge Installation and Troubleshooting Guide.
4
Pull the release latch on the Ethernet Switch Module outwards (perpendicular to the
module). The Ethernet Switch Module is released from the Dell Modular Server Chassis.
30
Installing the Ethernet Switch Module
Never remove the cover on a power supply or any part that has the following label

Advertisement

Table of Contents
loading

Table of Contents