ACL Metering Configuration

To display the following form, go to the ACL Configuration Table form, and select an ACL number, or open the
Access Control Lists folder and click Add ACL.
The following table describes the ACL Metering Configuration controls:
Table 171
ACL Metering Configuration controls
Control
Committed rate
(64 - 1000000 kb/s)
Maximum burst Size
(32 - -4096 kb/s)
Set out of profile to Drop or
Pass
Enable
Description
Configures the committed rate, in Kilobits per second. The committed rate must be a multiple
of 64.
Configures the maximum burst size, in Kilobits. Enter one of the following values for
: 32, 64, 128, 256, 512, 1024, 2048, 4096
mbsize
Configures the ACL Meter to either drop or pass out-of-profile traffic.
Enables or disables the ACL meter.