Table 6-2
Class: HP_NumericSensor
Property name
Description
ElementName
OperationalStatus[0]
StatusDescriptions[0]
HealthState
Name
CreationClassName
DeviceID
SystemCreationClassName
SystemName
EnabledDefault
Property implementation
Temperature Sensor n:Location detects for
NumericSensorType. StatusDescription,
where n represents the number of the temperature
sensor instance, NumericSensorType represents the
value of NumericSensorType, and
StatusDescription represents the value of
StatusDescriptions[0]
Temperature Sensor n:Location, where n represents the
number of the temperature sensor instance.
CIM_ManagedSystemElement
•
2 (OK)—if temperature reported by the sensor is
within normal operating range
•
2 (OK)—if temperature reported by the sensor has
exceeded its non-critical threshold and has set
fans to full speed
•
6 (Error)—if temperature reported by the sensor
has exceeded its threshold and the system is
gracefully shutting down
•
Temperature reported by the sensor
is within normal operating range—if
temperature reported by the sensor is within
normal operating range;
•
Temperature reported by the sensor
has exceeded its non-critical
threshold and the fans have been set
to full speed—if temperature reported by the
sensor has exceeded its threshold and has set fans
to full speed;
•
Temperature reported by the sensor
has exceeded its threshold and the
system is gracefully shutting down—
if OperationalStatus is 6 (Error)
•
5 (OK)—if OperationalStatus[0] value is 2 (OK);
•
20 (Major Failure)—if OperationalStatus[0] value
is 6 (Error)
Temperature Sensor n:Location, where n represents the
number of the temperature sensor instance.
CIM_LogicalDevice
HP_WinNumericSensor
Temperature Sensor n, where n is a unique identifier
for this temperature sensor instance.
HP_ComputerSystem.CreationClassName
HP_ComputerSystem.Name
CIM_EnabledLogicalElement
2 (Enabled)
System Temperature Sensor 76