HP BL860c Installation Manual

Insight management agents for linux release notes
Hide thumbs Also See for BL860c:

Advertisement

HP Insight Management Agents for Linux
Installation Guide and Release Notes
HP Integrity Servers with Linux
HP Part Number: 5991-2731
Published: March 2010
Edition: 16

Advertisement

Table of Contents
loading

Summary of Contents for HP BL860c

  • Page 1 HP Insight Management Agents for Linux Installation Guide and Release Notes HP Integrity Servers with Linux HP Part Number: 5991-2731 Published: March 2010 Edition: 16...
  • Page 2 © Copyright 2007–2010 Hewlett-Packard Development Company, L.P. Legal Notice Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license.
  • Page 3: Table Of Contents

    Advanced Troubleshooting Steps......................23 6 Release Notes.......................27 No Agent Support for the LSI1068 SAS I/O Controller in the rx2660 and BL860C/BL870C Servers..27 Storage Agents Do Not Display Serial Number and Firmware Version on SCSI Controller Cards..27 OpenIPMI Driver and hpima Fail Due to Baseboard Management Controller Initialization Failure..............................27...
  • Page 4 List of Tables HP Insight Management Agents Defined..................13 List of Tables...
  • Page 5: Edition

    Preface This document provides instructions for downloading and configuring HP Insight Management Agents on HP Integrity servers running Linux. As of this publication, these agents work with Red Hat Enterprise Linux (RHEL) and SUSE LINUX Enterprise Server (SLES). Based on the Simple Network Management Protocol (SNMP), HP Insight Management Agents allow you to remotely monitor configuration information and system status on your Integrity server from any SNMP browser.
  • Page 6: Related Information

    to the appropriate product support service. See your HP sales representative for details. For the latest version of this document online, see the HP Technical Documentation website: http://docs.hp.com/ Manufacturing Supported OS Supported Versions Edition Publication Date Part Number Number 5991-2731 Red Hat Enterprise Linux RHEL4U7, RHEL4U8, RHEL 5.3 March 2010...
  • Page 7: Hp Encourages Your Comments

    — HP products and services additional information: http://www.hp.com — For the location of the nearest sales office, call: In the United States: +1 800 637 7740 In Canada: +1 905 206 4725 In Japan: +81 3 3331 6111 In Latin America: +1 305 267 4220 In Australia/New Zealand: +61 3 9272 2895 In Asia Pacific: +8522 599 7777 In Europe/Africa/Middle East: +41 22 780 81 11...
  • Page 9: Overview

    1 Overview The HP Insight Management Agents provide system status information that you can monitor your system using HP Systems Insight Manager (SIM). The System Management Homepage is software that provides an interface between the management agents and the manageability tools, organizing information from HP Insight Management Agents for display in a web page.
  • Page 10: Hp Insight Management Agents

    HP Insight Management Agents The HP Insight Management Agents package is made of multiple components that monitor various aspects of system health and inventory. These components and their functions are: Foundation Agents: Provide event monitoring, installed software inventory, system utilization information, alarm thresholds. Server Agents: Provide event monitoring, system inventory, CPUs, PCI, memory, cellular information, LED states...
  • Page 11: Installing And Configuring Hp Insight Management Agents

    2 Installing and Configuring HP Insight Management Agents Follow the directions in this section to install, configure, and update HP Insight Management Agents. Concepts and Terms to Understand • SNMP operations - HP Insight Management Agents are based on the SNMP protocol, which includes the GET, SET, and TRAP operations defined as follows: —...
  • Page 12: Configuring Hp Insight Management Agent Packages

    During the process of installing the HP Insight Management Agent packages, default values are used to create an initial configuration. These default configuration values are stored in /etc/ snmp/snmpd.conf. Once the installation completes, the SNMP daemon and the HP Insight Management Agent packages start and messages similar to the following are displayed on your server: =================================================================== The following file(s) contained the prior snmpd configuration:...
  • Page 13: Configuring Polling Intervals

    Configuring Polling Intervals You can configure the HP Insight Management Agents polling intervals to accommodate your data collection needs. However, HP recommends that you use the default polling intervals unless you are performance tuning your system. You can list the process status table for all of the agents delivered with HP Insight Management Agent using the following command: # /etc/init.d/hpima status hpimaX (pid 29032) is running...
  • Page 14: Viewing A Polling Interval

    Obtaining the Community String You can obtain the rwcommunity string by viewing the /etc/snmp/snmpd.conf on your system and finding the line similar to the following: rwcommunity lYABuwPNFgmVCSkH 127.0.0.1 In this example, the rwcommunity string is set to lYABuwPNFgmVCSkH. Viewing a Polling Interval You can view the current polling interval for an agent with the snmpget command as follows: # snmpget -mALL -v1 -c<community string>...
  • Page 15 NOTE: The HPIMA_POLLFREQ is only available on HP Integrity systems running Linux. You can validate any changed agent polling intervals by using the snmpget command as described in “Viewing a Polling Interval” (page 14). NOTE: The snmpget/snmpset commands fail if the corresponding hardware is not present on the system.
  • Page 17: Reconfiguring Hp Insight Management Agents

    3 Reconfiguring HP Insight Management Agents If your system came with pre-installed HP Insight Management Agents, you need to reconfigure them to customize settings that require user-specific information, such as IP addresses and community strings. Before Reconfiguring Before beginning to reconfigure pre-installed HP Insight Management Agents software, you should check the version of your current software, and update your software to the latest version.
  • Page 18 Start Foundation Threshold Agent 'hpimathreshd': [ OK ] Start Server Health Agent 'hpimahealthd': [ OK ] Start Server Standard Equipment Agent 'hpimastdeqd': [ OK ] Start Storage Event Agent 'hpimaeventd': [ OK ] Start Storage Intelligent Disk Array Agent 'hpimaidad': [ OK ] Start Storage Serial Attached SCSI Agent 'hpimasasd': [ OK ] Start Storage SCSI Agent 'hpimascsid': [ OK ] Start Storage Fibre Channel Agent 'hpimafcad': [ OK ]...
  • Page 19: Installing And Configuring Hp System Management Homepage

    4 Installing and Configuring HP System Management Homepage Follow the directions in this section to install, configure, and update the HP System Management Homepage. Installing or Updating the HP System Management Homepage The HP System Management Homepage is installed on your system using the software installer, which is located on the HP Support Pack media of the HP Insight Foundation Suite for Integrity with Linux .
  • Page 21: Troubleshooting

    5 Troubleshooting This section provides instructions for troubleshooting basic agent installation and configuration issues. The following assumptions have been made to develop this information: □ The agents are not responding to inquiries from HP SIM. □ You are a Linux system administrator with root privilege. □...
  • Page 22: Shutting Down Iptables

    Shutting Down iptables WARNING! Inform your network administrator before you stop a running firewall, even momentarily. Disabling the firewall creates a potential security breach, and you must weigh this threat against the benefits of live troubleshooting. Enter /etc/init.d/iptables status and press Enter to see if the firewall software is installed and running.
  • Page 23: Advanced Troubleshooting Steps

    NOTE: The rocommunity ROlocal string, if it exists, must come before the rwcommunity <RWlocal> community string in the file. Find the directives for remote host community strings: rocommunity ROremote remote host name rwcommunity RWremote remote host name You should see a pair of lines for both the ROremote and the RWremote management stations you specified during agent installation.
  • Page 24 Turning on AgentX master support. NET-SNMP version <x.x.x> Wait at least ten seconds to ensure the daemon continues to run. Be aware that the next step might cause output to appear in this window. Examine the output for errors if the operations in the next step fail.
  • Page 25 If, while running RHEL, the values for PCI I/O slot numbers appear to be invalid (for example, PCI devices are not mapped to the physical slots in which they are installed), check the /var/log/hp/hpima file for the following message: Warning: hpima version <x.x> does not support multi-domain PCI If you find this message, you must reset your ACPI configuration value to single-pci-domain.
  • Page 27: Release Notes

    HP System Insight Manager to operate properly on the rx2660, BL860C, and BL870C servers. This issue is resolved with a special version of the mpt driver that HP has qualified, which can be downloaded from the HP Support website: Go to http://www.hp.com/.
  • Page 28 Reset the BMC: MP> CM MP:CM> RB Do you want to reset the BMC? (Y/[N]): Y -> BMC was issued a reset. Startup the hpima services: Shell> /etc/init.d/hpmgmtbase start Shell> /etc/init.d/hpima start Shell> /etc/init.d/hpwbem start Release Notes...

Table of Contents