Table 15-109
Property name
VariableValues
ImpactedDomain
BladeBay *
BladeName *
EnclosureName *
RackName *
RackUID *
SystemVirtualSerialNumber
SystemVirtualUUID
HWFirmwareVersion
HWLogicalLocation
HWManufacturer
HWSerialNumber
DeviceModel
15.4.11Controller Redundancy Has Been Lost
Table 15-110
Property name
IndicationIdentifier
PerceivedSeverity
IndicationTime
HPSA_DeviceIndication: Controller Redundancy state has been set to ACTIVE
HPSA_DeviceIndication: Controller Redundancy has been lost
Property implementation
•
VariableValues[0]: Short Description of failure
•
VariableValues[1]:
HPSA_ArrayController.CacheSizeTotal
•
VariableValues[2]:
HPSA_ArrayController.CacheSerialNumber
Note: In some cases the VariableValues property can
be N/A or "" (null).
•
3 (Enclosure) for c-Class blade systems
•
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
HP_BladeCSLocation.LocationInformation[0]
HP_ComputerSystem.Name
HP_BladeEnclosureCS.Name
Rack name if one exists
Rack Unique Identifier if one exists
Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment.
Conditional property containing the virtual system
UUID when running in a Virtual Connect environment.
HP_HardwareIndication
Array Controller firmware version string
Array Controller Location string
For example, Smart Array P600 in Slot 5
Array Controller Manufacturer string
Array Controller Serial Number
HP_DeviceIndication
Array Controller Model string
Property implementation
CIM_Indication
GUID string generated at time of ndication
3 (Warning)
Time of indication
Smart Array 260
Need help?
Do you have a question about the Integrity BL860c and is the answer not in the manual?
Questions and answers