HP Integrity BL860c Datasheet page 393

Insight management wbem providers for windows on integrity servers
Hide thumbs Also See for Integrity BL860c:
Table of Contents

Advertisement

Table 17-89
HPSAS_DeviceIndication: Enclosure Fan status changed to Failure
Property name
OSVersion
SystemFirmwareVersion
SystemSerialNumber
SystemProductID
SystemModel
SystemGUID
VariableNames
VariableTypes
VariableValues
ImpactedDomain
BladeBay *
BladeName *
EnclosureName *
RackName *
RackUID *
SystemVirtualSerialNumber
SystemVirtualUUID
HWLogicalLocation
HWSerialNumber
DeviceModel
Property implementation
The operating system version of the computer system
generating the indication in the format:
major.minor.build
Firmware version of the computer system generating
the indication
Serial number of the computer system generating the
indication
Product ID of the computer system generating the
indication
Model name of the computer system generating the
indication
Platform GUID of the computer system generating the
indication
FailureDescription
1 (String)
Short Description of failure
In some cases, VariableValues can be N/A or "" (null).
3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
HP_BladeCSLocation.LocationInformation[0]
HP_ComputerSystem.Name
HP_BladeEnclosureCS.Name
Rack name if one exists
Rack Unique Identifier if one exists
Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment.
Conditional property containing the virtual system
UUID when running in a Virtual Connect environment.
HP_HardwareIndication
Enclosure Location string
For example, Port 1I Box 1
Enclosure Serial Number
HP_DeviceIndication
Enclosure Model string
SAS HBA 393

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents