Table 18-78
Property name
HWLogicalLocation
HWSerialNumber
DeviceModel
18.4.18Fan Status Change – OK
Note: This indication might not be generated because the SCSI firmware does not report this
indication.
Table 18-79
Property name
CIM_Indication
IndicationIdentifier
PerceivedSeverity
IndicationTime
CIM_AlertIndication
Description
AlertingMangedElement
AlertingElementFormat
AlertType
EventID
EventTime
ProviderName
RecommendedActions
SystemName
SystemCreationClassName
Summary
EventCategory
ProbableCause
ProbableCauseDescription
HPSCSI_DeviceIndication: Temperature sensor status change—Critical
HPSCSI_DeviceIndication: Fan status change—OK
Property implementation
Enclosure Location string
Enclosure Serial Number
HP_DeviceIndication
Enclosure Model string
Property implementation
GUID string generated at time of indication
2 (Info)
Time of indication
The storage enclosure fan subsystem is operating
properly.
WBEM path of the HPSCSI_StorageEnclosureProcessor
class instance
2 (CIMObjectPath)
5 (Device Alert)
304
Time of the event or time of the indication if event time
unknown.
HP SCSI
No action is recommended.
Name of the computer system generating the indication
CreationClassName of the computer system generating
the indication
HP_AlertIndication
Fan status OK
24 (Primary Storage Cooling)
1 (Other)
Fan Status Changed to OK
SCSI HBA 455