17.4.17Enclosure Fan Status Changed to Degraded
Table 17-88
Property name
IndicationIdentifier
PerceivedSeverity
IndicationTime
Description
AlertingMangedElement
AlertingElementFormat
AlertType
EventID
EventTime
ProviderName
RecommendedActions
SystemName
SystemCreationClassName
Summary
EventCategory
ProbableCause
ProbableCauseDescription
ProviderVersion
NetworkAddresses
OSType
HPSAS_DeviceIndication: Enclosure Fan status changed to Degraded
Property implementation
CIM_Indication
GUID string generated at the time of indication
3 (Warning)
Time of indication
CIM_AlertIndication
A Storage Enclosure Fan status has changed to
Degraded. An enclosure has detected there may a
problem with one or more of the fans.
WBEM Path of HPSAS_StorageEnclosureProcessor
2 (CIMObjectPath)
5 (Device Alert)
305
Time of the event or time of the indication if event time
unknown
HP SAS
Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.
Name of the computer system generating the indication
CreationClassName of the computer system generating
the indication
HP_AlertIndication
Fan status Degraded
24 (Primary Storage Cooling)
94 (Fan failure)
Fan Degraded
Provider version generating the indication, in the form:
major.minor.revision.build.
Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
•
69 (Windows Server 2003 32-bit)
•
70 (Windows Server 2003 64-bit)
•
77 (Windows Server 2008 32-bit)
•
77 (Windows Server 2008 64-bit)
•
103 (Windows Server 2008 R2)
SAS HBA 390