Table 15-101
HPSA_DeviceIndication: Physical Drive status changed to ERROR
Property name
SystemSerialNumber
SystemProductID
SystemModel
SystemGUID
VariableNames
VariableTypes
VariableValues
ImpactedDomain
BladeBay *
BladeName *
EnclosureName *
RackName *
RackUID *
SystemVirtualSerialNumber
SystemVirtualUUID
HWFirmwareVersion
HWLogicalLocation
HWPhysicalLocation
DeviceControllerLogicalLocation
HWManufacturer
Property implementation
Serial number of the computer system generating the
indication
Product ID of the computer system generating the
indication
Model name of the computer system generating the
indication
Platform GUID of the computer system generating the
indication
•
VariableNames[0]: FailureDescription
•
VariableNames[1]: LastFailureDescription
•
VariableNames[2]: DriveInterface
•
VariableTypes[0]: 1 (String)
•
VariableTypes[1]: 1 (String)
•
VariableTypes[2]: 4 (uint16)
•
VariableValues[0]: Short Description of failure
•
VariableValues[1]: Short Description of last failure
•
VariableValues[2]: HPSA_DiskDrive.DriveInterface
•
3 (Enclosure) for c-Class blade systems
•
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
HP_BladeCSLocation.LocationInformation[0]
HP_ComputerSystem.Name
HP_BladeEnclosureCS.Name
Rack name if one exists
Rack Unique Identifier if one exists
Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment.
Conditional property containing the virtual system
UUID when running in a Virtual Connect environment.
HP_HardwareIndication
Physical Disk firmware version string
Physical Disk Location string
For example, Port:1E Box: 1 Bay: 5
Physical Location of the Failed Drive (Bay Number)
Controller Location
For example, SmartArray 642 in Slot 2
Compaq
Smart Array 242
Need help?
Do you have a question about the Integrity BL860c and is the answer not in the manual?