Hpsa_Storageenclosureprocessor - HP Integrity BL860c Datasheet

Insight management wbem providers for windows on integrity servers
Hide thumbs Also See for Integrity BL860c:
Table of Contents

Advertisement

Table 15-11
Property name
Tag
Version
RemovalConditions
Location

15.3.11HPSA_StorageEnclosureProcessor

HPSA_StorageEnclosureProcessor represents the management processor within a Storage Enclosure.
This instance contains the operational status for all managed components in the enclosure if
applicable.
Table 15-12
Property name
ElementName
OperationalStatus[0,1, 2, 3 ]
Class: HPSA_StorageEnclosure (HP_StorageEnclosure)
Class: HPSA_StorageEnclosureProcessor (CIM_ComputerSystem)
CIM_ManagedSystemElement
Property implementation
Opaque key
Not populated — Not available in this implementation
CIM_PhysicalPackage
2 (Not Applicable)
CIM_PhysicalFrame
CIM_Chassis
HP_StorageEnclosure
See HP Storage Enclosure Profile
HPSA_StorageEnclosure
Property implementation
CIM_ManagedElement
Port: m1,m2 Box: n, where m1 is the active port, m2 is
the passive port number, and n is the box number. For
dual port SAS disks, both port numbers are displayed.
Operational status for enclosure and associated power
supplies, fans and sensors. The use of
OperationalStatus is described in the HP Storage
Enclosure Profile. Index values are populated as
follows:
Index[0] – Enclosure status:
0 (Unknown)
2 (OK)
3 (Degraded)
6 (Error)
Index[1] – Fan status (See Profile)
Index[2] – Power Supply status (See Profile)
Index[3] – Temp Sensor Status (See Profile)
Note: Operational status for Fan, Power, and Temp
Sensor are "not detected" for internal storage
enclosure(s) of the local controller(s) (PCI or
Embedded).
Smart Array 201

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents