HP Integrity BL860c Datasheet page 373

Insight management wbem providers for windows on integrity servers
Hide thumbs Also See for Integrity BL860c:
Table of Contents

Advertisement

Table 17-79
HPSAS_DeviceIndication: Logical Drive status ERROR
Property name
EventTime
ProviderName
RecommendedActions
SystemName
SystemCreationClassName
Summary
EventCategory
ProbableCause
ProbableCauseDescription
ProviderVersion
NetworkAddresses
OSType
OSVersion
SystemFirmwareVersion
SystemSerialNumber
SystemProductID
SystemModel
SystemGUID
ImpactedDomain
BladeBay *
Property implementation
Time of the event or time of the indication if event time
unknown
HP SAS
Check for failed or removed physical drives.
Name of the computer system generating the indication
CreationClassName of the computer system generating
the indication
HP_AlertIndication
Logical drive status Error
6 (Primary Storage)
86 (Disk Failure)
Logical Drive Status Changed to Error
Provider version generating the indication, in the form:
major.minor.revision.build.
Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
69 (Windows Server 2003 32-bit)
70 (Windows Server 2003 64-bit)
77 (Windows Server 2008 32-bit)
77 (Windows Server 2008 64-bit)
103 (Windows Server 2008 R2)
The operating system version of the computer system
generating the indication in the following format:
major.minor.build
Firmware version of the computer system generating
the indication
Serial number of the computer system generating the
indication
Product ID of the computer system generating the
indication
Model name of the computer system generating the
indication
Platform GUID of the computer system generating the
indication
3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
HP_BladeCSLocation.LocationInformation[0]