Drive Status Predictive Failure - HP Integrity BL860c Datasheet

Insight management wbem providers for windows on integrity servers
Hide thumbs Also See for Integrity BL860c:
Table of Contents

Advertisement

17.4.6Drive Status PREDICTIVE FAILURE

Table 17-77
Property name
IndicationIdentifier
PreceivedSeverity
IndicationTime
Description
AlertingMangedElement
AlertingElementFormat
AlertType
EventID
EventTime
ProviderName
RecommendedActions
SystemName
SystemCreationClassName
Summary
EventCategory
ProbableCause
ProbableCauseDescription
ProviderVersion
NetworkAddresses
OSType
OSVersion
HPSAS_DeviceIndication: Drive status PREDICTIVE FAILURE
Property implementation
CIM_Indication
GUID string generated at the time of indication
5 (Major)
Time of indication
CIM_AlertIndication
A physical drive status has changed to Predictive
Failure.
WBEM Path of disk drive
2 (CIMObjectPath)
5 (Device Alert)
204
Time of the event or time of the indication if event time
unknown
HP SAS
Replace drive immediately to avoid loss of data.
Name of the computer system generating the indication
CreationClassName of the computer system generating
the indication
HP_AlertIndication
Physical drive predictive failure
6 (Primary Storage)
86 (Disk Failure)
Physical Drive Predictive Failure
Provider version generating the indication, in the form:
major.minor.revision.build.
Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
69 (Windows Server 2003 32-bit)
70 (Windows Server 2003 64-bit)
77 (Windows Server 2008 32-bit)
77 (Windows Server 2008 64-bit)
103 (Windows Server 2008 R2)
The operating system version of the computer system
generating the indication in the following format:
major.minor.build
SAS HBA 369