HP Integrity BL860c Datasheet page 253

Insight management wbem providers for windows on integrity servers
Hide thumbs Also See for Integrity BL860c:
Table of Contents

Advertisement

Table 15-106
HPSA_StorageVolumeIndication: Logical Drive status changed to Degraded
Property name
SystemProductID
SystemModel
SystemGUID
VariableNames
VariableTypes
VariableValues
ImpactedDomain
BladeBay *
BladeName *
EnclosureName *
RackName *
RackUID *
SystemVirtualSerialNumber
SystemVirtualUUID
HWLogicalLocation
DeviceOperationalStatus
Property implementation
Product ID of the computer system generating the
indication
Model name of the computer system generating the
indication
Platform GUID of the computer system generating the
indication
FailureDescription
1 (String)
Short Description of failure
Note: In some cases the "VariableValues" property can
be N/A or "" (null).
3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
HP_BladeCSLocation.LocationInformation[0]
HP_ComputerSystem.Name
HP_BladeEnclosureCS.Name
Rack name if one exists
Rack Unique Identifier if one exists
Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment.
Conditional property containing the virtual system
UUID when running in a Virtual Connect environment.
HP_HardwareIndication
Logical drive number and RAID Level. (for example,
LogicalDrive 1 (RAID 1+0)).
HP_DeviceIndication
HPSA_StorageVolumeIndication
Current OperationStatus values for Storage Volume
DeviceOperationalStatus[0]:
HPSA_StorageVolume.OperationalStatus[0]
DeviceOperationalStatus[1]:
HPSA_StorageVolume.OperationalStatus[1] (This
index is only populated if there is addional
Vendor unique status available)
Smart Array 253