Enclosure Fan Status Changed To Degraded - HP Integrity BL860c Datasheet

Insight management wbem providers for windows on integrity servers
Hide thumbs Also See for Integrity BL860c:
Table of Contents

Advertisement

15.4.26Enclosure Fan Status Changed to Degraded

Table 15-125
Property name
IndicationIdentifier
PerceivedSeverity
IndicationTime
Description
AlertingMangedElement
AlertingElementFormat
AlertType
EventID
EventTime
ProviderName
RecommendedActions
SystemName
SystemCreationClassName
Summary
EventCategory
ProbableCause
ProbableCauseDescription
NetworkAddresses
OSType
OSVersion
HPSA_DeviceIndication: Enclosure Fan status changed to Degraded
Property implementation
CIM_Indication
GUID string generated at time of indication
3 (Warning)
Time of indication
CIM_AlertIndication
A Storage Enclosure Fan status has changed to
Degraded. An enclosure has detected there may a
problem with one or more of the fans.
WBEM path of the HPSA_StorageEnclosureProcessor
2 (CIMObjectPath)
5 (Device Alert)
305
Time of the event or time of the indication if event time
unknown.
HP Smart Array
Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.
Name of the computer system generating the indication
CreationClassName of the computer system generating
the indication
HP_AlertIndication
Fan Status Degraded.
24 (Primary Storage Cooling)
94 (Fan failure)
Fan Degraded
A list of all the IP addresses (IPv4 and IPv6) of the
computer system generating the indication
69 (Windows Server 2003 32-bit)
70 (Windows Server 2003 64-bit)
76 (Windows Server 2008 32-bit)
77 (Windows Server 2008 64-bit)
103 (Windows Server 2008 R2)
Operating system version of the computer system
generating the indication in the format,
major.minor.build
Smart Array 293

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents