HP Integrity BL860c Datasheet page 323

Insight management wbem providers for windows on integrity servers
Hide thumbs Also See for Integrity BL860c:
Table of Contents

Advertisement

Table 16-38
HPFCHBA_DeviceIndication: Fibre Channel Port Status Changed to Link Down
Property name
Description
AlertingMangedElement
AlertingElementFormat
AlertType
EventID
EventTime
ProviderName
RecommendedActions
SystemName
SystemCreationClassName
Summary
EventCategory
ProbableCause
ProbableCauseDescription
NetworkAddresses
OSType
OSVersion
ProviderVersion
SystemFirmwareVersion
SystemSerialNumber
SystemProductID
Property implementation
CIM_AlertIndication
A fibre channel HBA port has changed to a state of
link down.
WBEM path of the HPFCHBA_DeviceIndication
2 (CIMObjectPath)
5 (Device Alert)
6
Time of the event or time of the indication if event time
is unknown.
HP Fibre Channel
Check the FC cabling to this port. Reinsert the FC
GBIC, if it has been unplugged. Replace the FC
cabling or the FC GBIC if failure continues.
HP_ComputerSystem.SystemName
HP_ComputerSystem.CreationClassName
HP_AlertIndication
FC HBA port state Unknown.
11 (I/O Adapter)
5 (Connection Establishment Error)
FC HBA Port State Changed to Link Down
A list of all the IP addresses (IPv4 and IPv6) of the
computer system generating the indication.
69 (Windows Server 2003 32-bit)
70 (Windows Server 2003 64-bit)
77 (Windows Server 2008 64-bit)
77 (Windows Server 2008 64-bit)
103 (Windows Server 2008 R2)
Operating system version of the computer system
generating the indication in the format,
major.minor.build
Provider version generating the indication, in the form:
major.minor.revision.build.
Firmware version of the computer system generating
the indication
Serial number of the computer system generating the
indication
Product ID of the computer system generating the
indication
FC HBA 323