Enclosure Temperature Sensor Status Changed To Critical - HP Integrity BL860c Datasheet

Insight management wbem providers for windows on integrity servers
Hide thumbs Also See for Integrity BL860c:
Table of Contents

Advertisement

17.4.15Enclosure Temperature Sensor Status Changed to
Critical
Table 17-86
Property name
IndicationIdentifier
PerceivedSeverity
IndicationTime
Description
AlertingMangedElement
AlertingElementFormat
AlertType
EventID
EventTime
ProviderName
RecommendedActions
SystemName
SystemCreationClassName
Summary
EventCategory
ProbableCause
ProbableCauseDescription
NetworkAddresses
OSType
HPSAS_DeviceIndication: Enclosure Temperature sensor status changed to Critical
Property implementation
CIM_Indication
GUID string generated at the time of indication
5 (major)
Time of indication
CIM_AlertIndication
A Storage Enclosure Temperature sensor status has
changed to Critical. An enclosure temperature is
reaching the maximum allowed temperature for normal
operation. A shutdown is imminent. Action is required
before loss of data occurs.
WBEM Path of HPSAS_StorageEnclosureProcessor
2 (CIMObjectPath)
5 (Device Alert)
309
Time of the event or time of the indication if event time
unknown
HP SAS
Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.
Name of the computer system generating the indication
CreationClassName of the computer system generating
the indication
HP_AlertIndication
Temperature sensor status Critical
24 (Primary Storage Cooling)
51 (Temperature Unacceptable )
Temperature Status Changed to Critical
Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
69 (Windows Server 2003 32-bit)
70 (Windows Server 2003 64-bit)
77 (Windows Server 2008 32-bit)
77 (Windows Server 2008 64-bit)
103 (Windows Server 2008 R2)
SAS HBA 386