Table 15-109
HPSA_DeviceIndication: Controller Redundancy state has been set to ACTIVE
Property name
ProviderName
RecommendedActions
SystemName
SystemCreationClassName
Summary
EventCategory
ProbableCause
ProbableCauseDescription
NetworkAddresses
OSType
OSVersion
ProviderVersion
SystemFirmwareVersion
SystemSerialNumber
SystemProductID
SystemModel
SystemGUID
VariableNames
VariableTypes
Property implementation
HP Smart Array
Check status of all controllers. A controller may have
failed causing this controller to become active.
Name of the computer system generating the indication
CreationClassName of the computer system generating
the indication
HP_AlertIndication
Controller redundancy state set to Active
6 (Primary Storage)
1 (Other)
Array Controller Redundancy State Changed to Active
A list of all the IP addresses (IPv4 and IPv6) of the
computer system generating the indication
•
70 (Windows Server 2003 64-bit)
•
77 (Windows Server 2008 64-bit)
•
103 (Windows Server 2008 R2)
Operating system version of the computer system
generating the indication in the format,
major.minor.build
Provider version generating the information, in the
form: major.minor.revision.build.
Firmware version of the computer system generating
the indication
Serial number of the computer system generating the
indication
Product ID of the computer system generating the
indication
Model name of the computer system generating the
indication
Platform GUID of the computer system generating the
indication
•
VariableNames[0]: FailureDescription
•
VariableNames[1]: CacheSizeTotal
•
VariableNames[2]: CacheSerialNumber
•
VariableTypes[0]: 1 (String)
•
VariableTypes[1]: 5 (uint16)
•
VariableTypes[2]: 1 (String)
Smart Array 259