Table 15-113
HPSA_DeviceIndication: Controller Battery status changed to not fully charged
Property name
SystemCreationClassName
Summary
EventCategory
ProbableCause
ProbableCauseDescription
NetworkAddresses
OSType
OSVersion
ProviderVersion
SystemFirmwareVersion
SystemSerialNumber
SystemProductID
SystemModel
SystemGUID
VariableNames
VariableTypes
VariableValues
Property implementation
CreationClassName of the computer system generating
the indication
HP_AlertIndication
Controller Battery Status set to Not fully Charged.
6 (Primary Storage)
99 (low battery)
Controller Battery Status Changed to Not Fully
Charged.
A list of all the IP addresses (IPv4 and IPv6) of the
computer system generating the indication
70 (Windows Server 2003 64-bit)
77 (Windows Server 2008 64-bit)
103 (Windows Server 2008 R2)
Operating system version of the computer system
generating the indication in the format,
major.minor.build
Provider version generating the information, in the
form: major.minor.revision.build.
Firmware version of the computer system generating
the indication
Serial number of the computer system generating the
indication
Product ID of the computer system generating the
indication
Model name of the computer system generating the
indication
Platform GUID of the computer system generating the
indication
VariableNames[0]: FailureDescription
VariableNames[1]: CacheSizeTotal
VariableNames[2]: CacheSerialNumber
VariableTypes[0]: 1 (String)
VariableTypes[1]: 5 (uint16)
VariableTypes[2]: 1 (String)
VariableValues[0]: Short Description of failure
VariableValues[1]:
HPSA_ArrayController.CacheSizeTotal
VariableValues[2]:
HPSA_ArrayController.CacheSerialNumber
Note: In some cases the VariableValues property can
be N/A or "" (null).