HP Integrity BL860c Datasheet page 279

Insight management wbem providers for windows on integrity servers
Hide thumbs Also See for Integrity BL860c:
Table of Contents

Advertisement

Table 15-118
HPSA_DeviceIndication: Enclosure Power Supply status changed to Non Redundant
Property name
ProviderName
RecommendedActions
SystemName
SystemCreationClassName
Summary
EventCategory
ProbableCause
ProbableCauseDescription
NetworkAddresses
OSType
OSVersion
ProviderVersion
SystemFirmwareVersion
SystemSerialNumber
SystemProductID
SystemModel
SystemGUID
VariableNames
VariableTypes
VariableValues
Property implementation
HP Smart Array
Check status of all enclosure power supplies. Ensure
that power supplies have not failed. Add or replace
power supplies as necessary.
Name of the computer system generating the indication
CreationClassName of the computer system generating
the indication
HP_AlertIndication
Power Supply status Non-Redundant
17 (Primary Storage Power)
89 (Power Supply Failure)
Redundant Power Supply Status Changed to Non-
Redundant
A list of all the IP addresses (IPv4 and IPv6) of the
computer system generating the indication
70 (Windows Server 2003 64-bit)
77 (Windows Server 2008 64-bit)
103 (windows Server 2008 R2)
Operating system version of the computer system
generating the indication in the format,
major.minor.build
Provider version generating the information, in the
form: major.minor.revision.build.
Firmware version of the computer system generating
the indication
Serial number of the computer system generating the
indication
Product ID of the computer system generating the
indication
Model name of the computer system generating the
indication
Platform GUID of the computer system generating the
indication
FailureDescription
1 (String)
Short Description of failure.
Note: In some cases the VariableValues property can
be N/A or "" (null).
Smart Array 279