Table 15-102
HPSA_DeviceIndication: Physical Drive status changed to REBUILDING
Property name
OSVersion
ProviderVersion
SystemFirmwareVersion
SystemSerialNumber
SystemProductID
SystemModel
SystemGUID
VariableNames
VariableTypes
VariableValues
ImpactedDomain
BladeBay *
BladeName *
EnclosureName *
RackName *
RackUID *
SystemVirtualSerialNumber
SystemVirtualUUID
HWFirmwareVersion
Property implementation
Operating system version of the computer system
generating the indication in the format,
major.minor.build
Provider version generating the information, in the
form: major.minor.revision.build.
Firmware version of the computer system generating
the indication
Serial number of the computer system generating the
indication
Product ID of the computer system generating the
indication
Model name of the computer system generating the
indication
Platform GUID of the computer system generating the
indication
•
VariableNames[0]: FailureDescription
•
VariableNames[1]: LastFailureDescription
•
VariableNames[2]: DriveInterface
•
VariableTypes[0]: 1 (String)
•
VariableTypes[1]: 1 (String)
•
VariableTypes[2]: 4 (uint16)
•
VariableValues[0]: Short Description of failure
•
VariableValues[1]: Short Description of last failure
•
VariableValues[2]: HPSA_DiskDrive.DriveInterface
•
3 (Enclosure) for c-Class blade systems
•
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
HP_BladeCSLocation.LocationInformation[0]
HP_ComputerSystem.Name
HP_BladeEnclosureCS.Name
Rack name if one exists
Rack Unique Identifier if one exists
Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment.
Conditional property containing the virtual system
UUID when running in a Virtual Connect environment.
HP_HardwareIndication
Physical Disk firmware version string
Smart Array 244