Temerature Sensor Status Change Warning Condition - HP Integrity BL860c Datasheet

Insight management wbem providers for windows on integrity servers
Hide thumbs Also See for Integrity BL860c:
Table of Contents

Advertisement

Table 18-76
Property name
DeviceModel

18.4.16Temerature Sensor Status Change Warning Condition

Note: This indication might not be generated because the SCSI firmware does not report this
indication.
Table 18-77
Property name
IndicationIdentifier
PerceivedSeverity
IndicationTime
Description
AlertingMangedElement
AlertingElementFormat
AlertType
EventID
EventTime
ProviderName
RecommendedActions
SystemName
SystemCreationClassName
Summary
EventCategory
ProbableCause
HPSCSI_DeviceIndication: Temperature sensor status change OK
HPSCSI_DeviceIndication: Temperature sensor status change Warning Condition
Property implementation
Enclosure Model string
Property implementation
CIM_Indication
GUID string generated at time of indication
4 (Minor)
Time of indication
CIM_AlertIndication
A Storage Enclosure Temperature sensor Status
changed to Warning Condition. This indicates the
enclosure temperature is above normal, otherwise
enclosure is still operating normally.
WBEM path of the HPSCSI_StorageEnclosureProcessor
class instance
2 (CIMObjectPath)
5 (Device Alert)
308
Time of the event or time of the indication if event time
unknown.
HP SCSI
Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.
Name of the computer system generating the indication
CreationClassName of the computer system generating
the indication
HP_AlertIndication
Temperature sensor status Warning Condition
24 (Primary Storage Cooling)
51 (Temperature unacceptable)
SCSI HBA 451

Hide quick links:

Advertisement

Table of Contents
loading