Table 15-108
HPSA_DeviceIndication: Controller status changed to ERROR
Property name
Summary
EventCategory
ProbableCause
ProbableCauseDescription
NetworkAddresses
OSType
OSVersion
ProviderVersion
SystemFirmwareVersion
SystemSerialNumber
SystemProductID
SystemModel
SystemGUID
VariableNames
VariableTypes
VariableValues
ImpactedDomain
Property implementation
Controller status Error
6 (Primary Storage)
24 (I/O device error)
Array Controller Status Changed to Error
A list of all the IP addresses (IPv4 and IPv6) of the
computer system generating the indication
•
70 (Windows Server 2003 64-bit)
•
77 (Windows Server 2008 64-bit)
•
103 (Windows Server 2008 R2)
Operating system version of the computer system
generating the indication in the format,
major.minor.build
Provider version generating the information, in the
form: major.minor.revision.build.
Firmware version of the computer system generating
the indication
Serial number of the computer system generating the
indication
Product ID of the computer system generating the
indication
Model name of the computer system generating the
indication
Platform GUID of the computer system generating the
indication
•
VariableNames[0]: FailureDescription
•
VariableNames[1]: CacheSizeTotal
•
VariableNames[2]: CacheSerialNumber
•
VariableTypes[0]: 1 (String)
•
VariableTypes[1]: 5 (uint16)
•
VariableTypes[2]: 1 (String)
•
VariableValues[0]: Short Description of failure
•
VariableValues[1]:
HPSA_ArrayController.CacheSizeTotal
•
VariableValues[2]:
HPSA_ArrayController.CacheSerialNumber
Note: In some cases the VariableValues property can
be N/A or "" (null).
•
3 (Enclosure) for c-Class blade systems
•
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
Smart Array 257
Need help?
Do you have a question about the Integrity BL860c and is the answer not in the manual?
Questions and answers