Ds1 And Ds1N Card Performance Monitoring Parameters; Figure 8-13 Monitored Signal Types For The Ds1 And Ds1N Cards; Figure 8-14 Pm Read Points On The Ds1 And Ds1N Cards - Cisco 15454-TCC - Network Processor Card Operation Manual

Operation guide
Hide thumbs Also See for 15454-TCC - Network Processor Card:
Table of Contents

Advertisement

Performance Monitoring for Electrical Cards

8.5.2 DS1 and DS1N Card Performance Monitoring Parameters

Figure 8-13
monitoring is supported for the DS1 card. Far-end DS1 path performance monitoring is not supported
for the DS1 card.
monitoring parameters for the DS1 and DS1N cards.

Figure 8-13 Monitored signal types for the DS1 and DS1N cards

ONS 15454
Note
The XX in the illustration above represents all PMs listed below with the given prefix and/or suffix.

Figure 8-14 PM read points on the DS1 and DS1N cards

Tx/Rx
Cisco ONS 15454 Installation and Operations Guide
8-18
shows the signal types that support far-end PMs. Far-end VT and STS path performance
Figure 8-14
shows where overhead bytes detected on the ASICs produce performance
Near End
DS1 Signal
DS1
OC48
DS1 Path (DS1 XX) Far End PMs Not Supported
VT Path (XX-V) Far End PMs Supported
STS Path (STS XX-P) Far End PMs Not Supported
DS1 and DS1N Cards
LIU
DS1 Tx AISS-P
DS1 Tx CV-P
DS1 Tx ES-P
DS1 Tx SAS-P
DS1 Tx SES-P
DS1 Tx UAS-P
DS1 CV-L
DS1 ES-L
DS1 SES-L
DS1 LOSS-L
DS1 Rx AISS-P
DS1 Rx CV-P
DS1 Rx ES-P
DS1 Rx SAS-P
DS1 Rx SES-P
DS1 Rx UAS-P
PMs read on LIU
Far End
DS1 Signal
Fiber
OC48
ONS 15454
Framer
DS1 Side
SONET Side
CV-V
ES-V
VT
SES-V
Level
BTC
UAS-V
STS CV-P
STS ES-P
Path
STS FC-P
Level
STS SES-P
STS UAS-P
PMs read on Framer
Chapter 8
Performance Monitoring
ONS 15454
DS1
XC10G Card
OC-N
November 2001

Advertisement

Table of Contents