Card Installation
Table 1-9
Card Type
TCC+
XC/XCVT/XC10G
Note
Verify that the ACT/STBY LED is the correct color for the card (green for active, amber for standby).
Step 6
The IP address for the node, the temperature of the ONS 15454, and the time of day will be displayed
on the LCD. The default time and date is 12:00 AM, January 1, 1970.
Tip
When a TCC+ card installed in the shelf assembly has a different version of the ONS 15454 software
installed than the version running on the active TCC+, the newly-installed TCC+ card automatically
loads the software version running on the active TCC+. You do not need to do anything in this
situation. However, the loading TCC+ card will not boot up in the normal manner. When the card is
first inserted, the red FAIL LED stays on for a short period. The FAIL LED then blinks normally and
all LEDs go dark. The FAIL LED and the ACT/STBY LED flash alternately every 30 to 45 seconds
as the new software loads onto the new TCC+ card. After loading the new software for approximately
30 minutes, the TCC+ card becomes the standby card and the amber LED is illuminated.

Procedure: Install Optical, Electrical, and Ethernet Cards

Although the installation procedure is the same for optical, electrical, and Ethernet cards, you must
install the optical cards before installing the electrical cards.
Before installing an OC-192 card, make sure the safety key on the faceplate is in off position
Warning
(labeled 0). When in the on position (labeled 1), the laser is activated.
Open the card ejectors.
Step 1
Cisco ONS 15454 Installation and Operations Guide
1-48
LED Activity during TCC+ and XC/XCVT/XC10G Card Installation
LED Activity
The red FAIL LED turns on and remains lit for 20 to 30 seconds.
1.
2.
The red FAIL LED blinks for 35 to 45 seconds.
The red FAIL LED remains lit for 5 to 10 seconds.
3.
4.
All LEDs (including the CRIT, MAJ, MIN, REM, SYNC, and ACO LEDs)
blink once and turn off for 5 to 10 seconds.
5.
The ACT/STBY LED turns on. (On the TCC+ card, the ACT/STBY LED
may take several minutes to illuminate while the DCC processor boots.)
1.
The red LED turns on and remains lit for 20 to 30 seconds.
2.
The red LED blinks for 35 to 45 seconds.
3.
The red LED remains lit for 5 to 10 seconds.
4.
All LEDs blink once and turn on.
5.
The ACT/STBY LED turns on.
If the FAIL LED is lit continuously on the TCC+ card, see the tip below about the TCC+
automatic upload.