Procedure: Provision External Alarms; Figure 7-5 External Alarms And Controls Using A Virtual Wire - Cisco 15454-TCC - Network Processor Card Operation Manual

Operation guide
Hide thumbs Also See for 15454-TCC - Network Processor Card:
Table of Contents

Advertisement

Chapter 7
Card Provisioning
Figure 7-5
Smoke
detector
When using AIC virtual wires, you can:

Procedure: Provision External Alarms

Step 1
Wire the external-device relays to the ENVIR ALARMS IN backplane pins. See the
LAN, and Craft Pin Connections" section on page 1-32
Step 2
Log into the node in CTC and display the AIC in card view.
Step 3
Click the Provisioning > External Alarms tabs
Step 4
Complete the following fields for each external device wired to the ONS 15454 backplane:
November 2001
External alarms and controls using a virtual wire
Smoke
detector
Virtual Wire #1
ONS 15454
Node 4
Virtual Wire #1
Assign different external devices to the same virtual wire.
Assign virtual wires as the trigger type for different external controls.
Enabled—Click to activate the fields for the alarm input number.
Alarm Type—Select an alarm type from the provided list.
Bell
Virtual Wire #1 is
external control
trigger
ONS 15454
Node 1
ONS 15454
Node 2
ONS 15454
Node 3
Smoke
detector
for more information.
(Figure 7-6 on page
Cisco ONS 15454 Installation and Operations Guide
Provisioning the Alarm Interface Controller
Virtual Wire #1
Smoke
detector
Virtual Wire #1
= External alarm
= External control
"Alarm, Timing,
7-28).
7-27