Figure 47: Removing the removable media board
12. Lift the board out gently, being careful of the slimline drive bay connector.
Reverse steps 1 through 12 to replace the removable media board.

Rear Fan Cage

To remove the rear fan cage:
1. Power down the server. Refer to "Powering Down the Server" in this chapter.
2. Extend the server from the rack. Refer to "Extending the Rack from the Server" in this
3. Open the rear access panel. Refer to "Opening and Removing the Rear Access Panel" in
4. Remove the hot-plug fans in the rear fan cage. Refer to "Hot-Plug Fans" in this chapter.
5. Remove the processor air baffle. Refer to "Processor Air Baffle" in this chapter.
6. Remove the memory boards. Refer to "Removing a Memory Board" in this chapter.
7. Loosen the two thumbscrews that secure the rear fan cage to the chassis (1).
8. Remove the rear fan cage from the chassis (2).
NAS e7000 v2 Maintenance and Service Guide
1
2
chapter.