Compaq 230039-001 - StorageWorks NAS Executor E7000 Model 904 Server Maintenance And Service Manual page 121

Hp storageworks nas e7000 v2 maintenance and service guide
Hide thumbs Also See for 230039-001 - StorageWorks NAS Executor E7000 Model 904 Server:
Table of Contents

Advertisement

Table 37: Is the System Power LED Off?
Answer
Yes, it is off
No
Note: For LED locations and functions, refer to Chapter 4, "Connectors, LEDs, and Switches." For
cabling configurations, refer to the setup and installation guide.
NAS e7000 v2 Maintenance and Service Guide
Possible Reasons
The system is not connected to AC
power, or no AC power is available.
A power supply problem exists. The
power supply may not be connected or
inserted properly, it may have a
damaged connector, or it may have
failed.
There is a broken connection between
the front panel LED assembly and the
removable media board.
The front panel LED assembly has failed.
If the system power button LED is amber, press the Power On/Standby button.
Refer to
Table
38.
Troubleshooting
Possible Solutions
Be sure that the power cord is
connected to the power supply.
Be sure that the power supply is
undamaged and fully seated, and
then be sure that the power supply
LED is green when you power up
the server. Refer to Chapter 4,
"Connectors, LEDs, and Switches,"
for locations and states.
Be sure that the power switch cable
assembly is inserted properly to the
removable media board.
Servers Troubleshooting
Refer to the
Guide
for further options regarding
power problems and general
hardware problems.