Hot-Plug Fans - Compaq 230039-001 - StorageWorks NAS Executor E7000 Model 904 Server Maintenance And Service Manual

Hp storageworks nas e7000 v2 maintenance and service guide
Hide thumbs Also See for 230039-001 - StorageWorks NAS Executor E7000 Model 904 Server:
Table of Contents

Advertisement

Table 13: Recommended PCI-X Expansion Slot Population Order
The operating system detects the PCI-X devices in the slots in this order:
6-5-4-3-2-1
For more information about PCI-X bus architecture and numbering, refer to the white paper,
PCI Bus Numbering in a Windows NT Environment, on the product website at

Hot-Plug Fans

To remove a hot-plug fan:
1. Extend the server from the rack. Refer to "Extending the Server from the Rack" in this
2. Open the rear access panel. Refer to "Opening and Removing the Rear Access Panel" in
3. Identify the failed fan by locating the fan with the amber LED.
4. Pull the tabs on the top of the fan (1).
5. Remove the fan from the server (2).
NAS e7000 v2 Maintenance and Service Guide
Slot Number
6
5
4
3
2
1
Caution:
Do not attempt to remove and replace a fan as a hot-plug procedure unless the
fan zone is redundant.
chapter.
this chapter.
Population Order
1
4
2
5
3
6
Removal and Replacement Procedures
Bus Sharing
Shared PCI-X bus 10
Shared PCI-X bus 6
Shared PCI-X bus 2
www.hp.com
.