Compaq 219700-001 - ProLiant - 1500 User Manual

Compaq 219700-001 - ProLiant - 1500 User Manual

User guide: online storage controller recovery option
Hide thumbs Also See for 219700-001 - ProLiant - 1500:
Table of Contents

Advertisement

O
NLINE STORAGE
CONTROLLER RECOVERY
OPTION
USER GUIDE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 219700-001 - ProLiant - 1500 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Compaq 219700-001 - ProLiant - 1500

  • Page 1 NLINE STORAGE CONTROLLER RECOVERY OPTION USER GUIDE...
  • Page 2 ......Online Storage Controller Recovery Option User Guide First Edition (September 1997) Part Number 295586-001 Compaq Computer Corporation...
  • Page 3 This test is not a determination of product quality or correctness, nor does it ensure compliance with any federal, state, or local requirements. Compaq does not warrant products other than its own strictly as stated in Compaq product warranties.
  • Page 4: Table Of Contents

    How this Guide is Arranged ..................vii Symbols In Text......................viii Symbols in Equipment ....................ix Getting Help ........................xi Telephone Numbers ....................xi Compaq Web Site....................xiii Chapter 1 Elements of the Online Storage Controller Recovery Option Solution Hardware Requirements ....................1-1 Software Requirements ....................1-2 Kit Contents........................
  • Page 5 Installing the Recovery Server Switch in the ProLiant Storage System/F or /U .. 3-6 Upgrading the SMART-2 Array Controller Firmware ......... 3-9 Updating the SMART-2 Array Controller Device Drivers......... 3-10 Loading the Compaq SSD for Windows NT ............3-10 Installation ........................3-13 Installing the Controllers..................3-14 Labeling the Cables .....................
  • Page 6 ......Chapter 5 Troubleshooting Controllers Must Be Matched ..................5-1 Planning for OSCRO when RSO is in Use ..............5-1 Incorrect Cabling ......................
  • Page 7 Japanese Notice ......................B-3 Australian Notice......................B-3 Appendix C Building Diskettes from the SmartStart and Support Software CD Building Diskettes for the SMART-2 Array Controller Firmware Upgrade ....C-1 Building Diskettes for the Compaq System Configuration Utility version 2.36 rev. A ......................C-4 Index...
  • Page 8: How To Use This Guide

    This section provides step-by-step instructions for planning and installing OSCRO. Chapter 4 - Compaq Online Storage Recovery Utility This section describes the use of the Compaq Online Storage Controller Recovery Utility. Chapter 5 - Troubleshooting This section describes error conditions and incorrect configurations of OSCRO.
  • Page 9: Symbols In Text

    ......viii How To Use This Guide Appendixes include important information related to electrostatic discharge, regulatory compliance notices, and how to build diskettes from the SmartStart and Support Software CD.
  • Page 10: Symbols In Equipment

    ......Text Conventions Convention Keys Keys appear in boldface. A plus sign (+) between two keys indicates that they should be pressed simultaneously.
  • Page 11 ......How To Use This Guide WARNING: Any surface or area of the equipment marked with these symbols indicates the presence of electrical shock hazards.
  • Page 12: Getting Help

    If you have a problem and have exhausted the information in this guide, you can get further information and other help in the following locations. Telephone Numbers Contact your nearest Compaq Authorized Reseller or Service Provider for more information. For the name of your nearest Compaq Authorized Reseller:...
  • Page 13 ......How To Use This Guide Compaq Worldwide Technical Support Telephone Numbers Continued...
  • Page 14: Compaq Web Site

    ......xiii Compaq Web Site The Compaq Web site has information on this product as well as the latest drivers and Flash ROM images. You can access the Compaq Web site by logging on to the Internet at http://www.compaq.com.
  • Page 15: Elements Of The Online Storage Controller Recovery Option Solution

    The following hardware components are required for OSCRO: Compaq ProLiant or ProSignia server For some server models, a knockout panel Two Compaq SMART-2 Array Controllers of the same type Compaq ProLiant Storage System(s)/F or /U Fast-Wide SCSI cables (either 6 or 12 feet in length) to connect...
  • Page 16: Software Requirements

    OSCRO is supported only under Windows NT 4.0. All software required to implement OSCRO is on the Compaq SmartStart and Support Software CD included in the kit. This CD includes the Compaq Support Software for Microsoft Windows NT (SSD) (version 2.02 or later) and updated firmware and device drivers for the Compaq SMART-2 Array Controllers.
  • Page 17: Kit Contents

    The ROMPaq for the SMART-2 firmware upgrade (version 1.94 or later) is included on the SmartStart and Support Software CD in the Recovery Server Option /U kit. It can also be found on the Compaq Web site. Kit Contents The Recovery Server Option /U kit (part number 304117-B21) includes...
  • Page 18 ......Elements of the Online Storage Recovery Option Solution The contents of the Recovery Server Option /U kit are illustrated in Figure 1-2.
  • Page 19: Functionality And Configuration Options

    With the introduction of OSCRO and its two-way switching capability, Compaq offers fault tolerance for mass storage controllers implemented at the hardware level, providing increased reliability without the need for complete I/O subsystem redundancy.
  • Page 20: Merging Two Smart-2 Controllers Into A Controlled Pair

    ......Functionality and Configuration Options Merging two SMART-2 Controllers into a Controlled Pair OSCRO allows you to merge two matched SMART-2 controllers into a controller pair.
  • Page 21 OSCRO extends the reliability of Windows NT servers by ensuring continuing operation of the system, even when a mass storage controller fails. The Compaq Online Storage Controller Recovery Utility for Windows NT provides a means of managing the mass storage controllers of the entire Windows NT network from a single management station.
  • Page 22: Configuration Options

    ......Functionality and Configuration Options Configuration Options This section outlines the configuration guidelines involved in establishing highly reliable I/O using OSCRO.
  • Page 23 ......SMART-2 Array Controllers implement RAID fault tolerance at the hardware level, eliminating the overhead associated with implementing RAID in the software.
  • Page 24: Single-Channel Configuration

    The simplest OSCRO configuration involves two SMART-2 Array Controllers and a single ProLiant Storage System/F or /U equipped with the Recovery Server Switch. The Compaq Online Storage Controller Recovery Utility is used to merge the independent controllers into a controller pair. One controller is the active controller, and the other is designated the standby controller.
  • Page 25 ......ProLiant Storage System /F or /U Standby Active Device Driver Figure 2-2.
  • Page 26: Dual-Channel Configuration

    ......Functionality and Configuration Options This configuration rule is especially significant when the system boot device is connected to a controller pair.
  • Page 27: Multiple Controller Pairs

    ......ProLiant ProLiant Storage Storage System System /F or /U /F or /U Standby Active Device...
  • Page 28: Internal Vs. External Boot Device

    ......2-10 Functionality and Configuration Options The number of possible controller pairs may be limited by the number of knockout panels or slots (see Figure 3-6) available on the server as well as the number of available expansion slots for SMART-2 controllers.
  • Page 29: Planning And Installing The Online Storage Controller Recovery Option

    Hardware Planning The first step toward OSCRO implementation is hardware planning. You must have at least one Compaq ProLiant or ProSignia server, at least two SMART-2 Array Controllers of the same type, and at least one Compaq ProLiant Storage System/F or /U.
  • Page 30: Dual-Channel Configuration Considerations

    ......Planning and Installing the Online Storage Controller CAUTION: SMART-2 Array Controllers use different disk geometries than standard SCSI adapters.
  • Page 31: Oscro Planning Implications

    ......OSCRO Planning Implications There are several things to consider before installing OSCRO. They include thinking about your current environment in terms of the following: The Recovery Server Option /U kit contains parts for three different high-availability option solutions.
  • Page 32: Potential Impact On Unattended Reboot

    ......Planning and Installing the Online Storage Controller Potential Impact on Unattended Reboot Installation of OSCRO effectively sets up a standby mass storage controller.
  • Page 33: Array Acceleration Disabled

    Recovery Server Option Incompatibility Compaq Recovery Server Option consists of the Standby Recovery Server and the On-Line Recovery Server. OSCRO cannot be run in conjunction with either Recovery Server Option because both require hardware connectivity to ProLiant Storage Systems through the same interfaces and, although the cables are the same type, the cabling requirements are not compatible.
  • Page 34: Installing The Recovery Server Switch In The Proliant Storage System/F Or /U

    ......Planning and Installing the Online Storage Controller These tasks, which should be performed in the order presented, are described in this section.
  • Page 35 ......FIG059.EPS Figure 3-1. Removing the Fast-Wide SCSI Interface Module in a Tower Server Carefully slide in the Recovery Server Switch (Part Number 007678-001) as shown in Figure 3-2.
  • Page 36 ......Planning and Installing the Online Storage Controller Switch Installation in a Rack Mount To install the Recovery Server Switch in a rack-mount ProLiant Storage System/F or /U: Make sure the power on the ProLiant Storage System is turned off.
  • Page 37: Upgrading The Smart-2 Array Controller Firmware

    Figure 3-4. Sliding in the Recovery Server Switch in a Rack-Mount Server Upgrading the SMART-2 Array Controller Firmware The firmware upgrade for SMART-2 Array Controllers is on the Compaq SmartStart and Support Software CD. To upgrade the firmware, follow the instructions on the ROMPaq (version 2.39, which contains SMART-2 Array Controller firmware 1.94), heeding all of the warnings and restriction...
  • Page 38: Updating The Smart-2 Array Controller Device Drivers

    OSCRO. Run SETUP.EXE from CPQSUPSW\NTSSD. When the Setup Utility for the Compaq SSD for Windows NT is running, the screen shown in Figure 3-5 is displayed. This screen lists the options available. To install OSCRO, highlight the Compaq Online Storage Controller Recovery line and click the Install or...
  • Page 39 Figure 3-5. Compaq SSD for Windows NT Setup Screen The screen shown in Figure 3-5 shows all of the components provided by the Compaq SSD for Windows NT. Table 3-1 describes the components that are and are not required for implementing the Online Storage Controller Recovery Option.
  • Page 40 The CPQRCMC service is required when implementing OSCRO on Service the local server or when setting up remote management capability. CPQRCMC acts as the central communications point for the Compaq Online Storage Controller Recovery Utility as well as the PCI Hot Plug Utility.
  • Page 41: Installation

    Using the Express option directs Setup to detect the devices and software options installed on your system that could be updated with the newer versions on the Compaq SSD for Windows NT. After clicking the Express button, a screen is displayed that shows the options Setup will install. From this screen you can select or deselect any of the options shown.
  • Page 42: Installing The Controllers

    ......3-14 Planning and Installing the Online Storage Controller Installing the OSCRO software Making one or more controller pairs If the controllers you will be using for OSCRO are already installed and configured, go to the next section, “Labeling the Cables.”...
  • Page 43: Labeling The Cables

    ......3-15 On the System Configuration Menu, select Configure Hardware. When the automatic configuration is completed, you are given the option to Save changes and exit, or Review and modify hardware settings.
  • Page 44: Connecting The Cables

    ......3-16 Planning and Installing the Online Storage Controller Table 3-2 Cable Labeling Example Cable Label Description...
  • Page 45 ......3-17 Depending on which server you have, you may need to look on the back of the server case and locate the knockout panel or the plate that covers the hole for the knockout panel.
  • Page 46 ......3-18 Planning and Installing the Online Storage Controller 4 3 2 Stripe Figure 3-7.
  • Page 47 ......3-19 Internal Connector External Connector Figure 3-8. Dual-Channel SMART-2 Array Controller Connectors Locate the four external cables used to connect the server to the ProLiant Storage Systems (part number 189646-003).
  • Page 48: Merging Two Controllers Into A Controller Pair

    Planning and Installing the Online Storage Controller Merging Two Controllers into a Controller Pair To make a controller pair: Access the Compaq Online Storage Controller Recovery Utility by double-clicking the Compaq Online Storage Recovery applet in the Control Panel, or in the Compaq System Tools folder.
  • Page 49 ......3-21 Click the Merge button to continue the process. The Compaq Online Storage Controller Recovery Utility prompts you to confirm the decision to merge the two controllers by displaying the dialog box shown in Figure 3-10.
  • Page 50: Testing And Verifying The Installation

    ......3-22 Planning and Installing the Online Storage Controller Figure 3-11. Merge Completed and Pair Active The active controller icon is green;...
  • Page 51 If failure is indicated, make sure the cables are all attached and correctly configured, then rerun the Verify process. The Verify function in the Compaq Online Storage Controller Recovery Utility takes over 80 seconds. During this process, all three icons have yellow X’s over them indicating the controllers and the pair are Not Ready for use.
  • Page 52: Compaq Online Storage Controller Recovery Utility

    OSCRO controller pairs. This utility can be accessed from the Compaq Online Storage Recovery applet in either the Control Panel or the Compaq System Tools folder. Each SMART-2 Array Controller is displayed showing its controller type and its physical location. The color of the icon indicates whether it is part of a controller pair.
  • Page 53: Right-Click Functionality

    Compaq Online Storage Controller Recovery Utility Right-Click Functionality In addition to the primary functions, the Compaq Online Storage Controller Recovery Utility provides several secondary functions that are available by right-clicking the mouse button on a selected controller or controller pair.
  • Page 54: Mass Storage Controller Icons

    Mass Storage Controller Icons There are eight different mass storage controller icons that display on the left side of Compaq Online Storage Controller Recovery Utility main screen. Table 4-1 describes each icon. Online Storage Controller Recovery Option User Guide...
  • Page 55 ......Compaq Online Storage Controller Recovery Utility Table 4-1 Mass Storage Controller Icons...
  • Page 56 ......Figure 4-3 shows the main screen of the Compaq Online Storage Controller Recovery Utility when two SMART-2 controllers are connected to a ProLiant Storage System/F or /U through the Recovery Server Switch.
  • Page 57: Viewing Device Properties

    Pair Normal Viewing Device Properties When a specific mass storage controller is selected on the Compaq Online Storage Controller Recovery Utility screen, the General and Status properties of that controller can be displayed. Selection can be made by double-clicking a specific controller or selecting the Properties function on the right-click menu.
  • Page 58 ......The General properties screen shown in Figure 4-4 provides information about the physical and logical locations of the device.
  • Page 59 ......Compaq Online Storage Controller Recovery Utility The Status properties page shown in Figure 4-5 provides information about the status of the PCI Hot Plug slot (when applicable) and the mass storage controller.
  • Page 60 ......Table 4-3 Status Properties Indicators      Slot Lever Closed Slot release lever is in the Slot release lever is in the open closed position.
  • Page 61: Setting Machine Options

    ......4-10 Compaq Online Storage Controller Recovery Utility Setting Machine Options Right-clicking the title bar of the Online Storage Controller Recovery Utility brings up the System menu for the utility.
  • Page 62: Troubleshooting

    ......Chapter 5 Troubleshooting If you are unable to perform a task associated with OSCRO, make sure you have the privilege associated with the task.
  • Page 63: Cross Connection

    ......Configuration Errors to Avoid It is important to understand that the Online Storage Controller Recovery Utility detects cabling errors when the Verify function is used to test all OSCRO controller pairs.
  • Page 64 ......ProLiant ProLiant Storage Storage System System /F or /U /F or /U Standby Active Device...
  • Page 65: Unilateral Connection

    ......Configuration Errors to Avoid Unilateral Connection In the example shown in Figure 5-2, both the internal and external cables from the active controller are connected to the same ProLiant Storage System/F or /U.
  • Page 66 ......ProLiant ProLiant Storage Storage System System /F or /U /F or /U Standby Active Device...
  • Page 67: Mismatched Controller Pairs

    ......Configuration Errors to Avoid Mismatched Controller Pairs OSCRO allows you to form multiple controller pairs in a single server. Each controller pair must conform to the configuration guidelines for single-channel or dual-channel controller pairs.
  • Page 68: Clearing A Cable Check Error

    Wrong Device Driver If you get the message unknown error 0xed0e0000 you are running with old device drivers. Use the Compaq SSD for Windows NT that is included in the Recovery Server Option /U kit, to update the controller device drivers.
  • Page 69: Boot Device Considerations

    ......Configuration Errors to Avoid Boot Device Considerations After a controller failover, there are situations in which the system will not be able to boot.
  • Page 70: Recovering From Mass Storage Controller Failure

    ......Chapter 6 Recovering from Mass Storage Controller Failure OSCRO enables the server to continue operating even when a mass storage controller fails.
  • Page 71 Figure 6-1. Compaq PCI Hot Plug Technology Recovery from Controller Failure with OSCRO Using this procedure, the fault-tolerant state of the I/O subsystem is restored without shutting down the system or interrupting the availability of the data.
  • Page 72: Recovering From Mass Storage Controller Failure Without Pci Hot Plug Technology

    ......Recovering from Mass Storage Controller Failure Without PCI Hot Plug Technology The steps for recovering from mass storage controller failure when you do not have PCI Hot Plug Technology are: Schedule a time when the server can be shut down.
  • Page 73 ......Recoving from Mass Storage Controller Failure We strongly suggest you repair the boot device controller while the server is shut down.
  • Page 74: Dissolving A Controller Pair

    Access the Online Storage Controller Recovery Utility from the Compaq Online Storage Recovery applet on the Control Panel, or from the Compaq System Tools folder. Highlight the controller pair you want to dissolve (the highlighted line must have a white icon).
  • Page 75 ......Dissolving a Controller Pair Click the Dissolve button. A dialog box asks you to confirm that you want to dissolve the controller pair (see Figure 7-1).
  • Page 76: Appendix A Electrostatic Discharge

    ......Appendix A Electrostatic Discharge A discharge of static electricity from a finger or other conductor may damage printed circuit boards or other static-sensitive devices.
  • Page 77 If you do not have any of the suggested equipment for proper grounding, have an Authorized Compaq Service Provider install the part. NOTE: For additional information on static electricity or assistance with the installation of the product, contact your Authorized Compaq Service Provider or refer to the Maintenance and Service Guide.
  • Page 78: Regulatory Compliance Notices

    Modifications The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Compaq Computer Corporation may void the user's authority to operate the equipment. Cables...
  • Page 79: European Union Notice

    ......B-2 Regulatory Compliance Notices European Union Notice Products with the CE Marking comply with both the EMC Directive (89/336/EEC) and the Low Voltage Directive (73/23/EEC) issued by the Commission of the European Community.
  • Page 80: Australian Notice

    ......Australian Notice This customer equipment is to be installed and maintained by service personnel as defined by AS/NZS 3260 Clause 1.2.14.3.
  • Page 81: Building Diskettes From The Smartstart And Support Software Cd

    If you do not have an Integration Server in your environment, or if the Integration Server does not have the latest software, you should select the CD Only option, then click Next>. The Compaq SmartStart - Diskette Builder screen changes to a browser screen. Online Storage Controller Recovery Option User Guide...
  • Page 82 ......C-2 Building Diskettes from the SmartStart CD Figure C-1. SmartStart Diskette Builder Screen Scroll down to the entry called Options ROMPaq 2.39.
  • Page 83 ......Figure C-2. Diskette Builder Verification Screen If the diskette is not blank, you are warned that the operation will destroy all data on the diskette.
  • Page 84: Building Diskettes For The Compaq System Configuration Utility Version 2.36 Rev. A

    If you do, put a check in the box that says I Agree and click OK. The Compaq SmartStart - Diskette Builder screen offers the option to build the diskettes from the CD only or build them from the Integration Server and the CD.
  • Page 85 ......Figure C-3. SmartStart Diskette Builder Screen Scroll down to the entry called System Configuration Utility. Place an X in the box.
  • Page 86 ......C-6 Building Diskettes from the SmartStart CD Figure C-4. Diskette Builder Verification Screen If the diskette is not blank, you are warned that the operation will destroy all data on the diskette.
  • Page 87 5-1 Dissolving mismatched controller pairs a controller pair 7-1 Dual-channel configuration 2-8 Comments where to send xiii Compaq Online Storage Controller Recovery Utility 3-19, 4-1 to Electrostatic discharge A-1 4-10, 7-1 Email address xiii Compliance notices B-1 Configuration dual-channel 2-8...
  • Page 88 ......I-2 Index F1 boot prompt 3-4 Labeling the cables 3-15 disabling 3-15 Fail/Unfail 4-2 Firmware...
  • Page 89 Recovery Server Option 3-3, 5-1 the installation 3-22 Refresh 4-1 Requirements hardware 1-1 software 1-2 Web site Right-click functionality 4-2 Compaq xiii Windows NT upgrade 3-3 Windows NT Support Software Single-channel configuration 2-6, components 3-12 3-16 Software requirements 1-2 components 3-12...

Table of Contents