Compaq 230039-001 - StorageWorks NAS Executor E7000 Model 904 Server Maintenance And Service Manual page 97

Hp storageworks nas e7000 v2 maintenance and service guide
Hide thumbs Also See for 230039-001 - StorageWorks NAS Executor E7000 Model 904 Server:
Table of Contents

Advertisement

Table 22: Hot-Plug SCSI Hard Drive LED Combinations
Activity
Flashing
flashing
NAS e7000 v2 Maintenance and Service Guide
Online
LED
LED
On
Off
On
Flashing
Flashing
Flashing
Off
Off
Off
Off
Off
On
On or
On
Fault
LED
Status
Off
Do not remove the drive. Removing a drive during this
process will cause data loss.
The drive is being accessed and is not configured as part
of an array.
Off
Do not remove the drive. Removing a drive during this
process will cause data loss.
The drive is rebuilding or undergoing capacity expansion.
Do not remove the drive. Removing a drive during this
process will cause data loss.
The drive is part of an array being selected by the Array
Configuration Utility.
-Or-
The Options ROMPaq is upgrading the drive.
Off
OK to replace the drive online if a predictive failure alert
is received, and the drive is attached to an array
controller.
The drive is not configured as part of an array.
-Or-
If this drive is part of an array, then a powered-on
controller is not accessing the drive.
-Or-
The drive is configured as an online spare.
On
OK to replace the drive online.
The drive has failed and has been placed off line.
Off
OK to replace the drive online if a predictive failure alert
is received, provided that the array is configured for fault
tolerance and all other drives in the array are online.
The drive is online and configured as part of an array.
Off
Do not remove the drive. Removing a drive during this
process will cause data loss.
The drive is online and being accessed.
Connectors, LEDs, and Switches