Analog Reference Voltage Output; Dc Voltage Output - Danfoss iC7 Series Design Manual

Air-cooled system modules
Hide thumbs Also See for iC7 Series:
Table of Contents

Advertisement

Design Guide | iC7 Series Air-cooled System Modules
Table 35: Relay Output Values (continued)
Parameter
Operate Time Max.
Release Time Max.
DC Breaking Capacity
B
[VDC]
100
10
0.1
Figure 47: Maximum DC Load Breaking Capacity
B
DC voltage

Analog Reference Voltage Output

8.9.6
The I/O and Relay Option contains 1 analog reference voltage output.
Table 36: Analog Reference Voltage Output Values
Parameter
Nominal Voltage
Accuracy
Maximum Output Current
Short Circuit Current
Electrical fast transient (EFT)
24 V DC Voltage Output
8.9.7
The I/O and Relay Option contains 1 voltage output of 24 V DC.
Table 37: 24 V DC Voltage Output
Parameter
Nominal Voltage
Accuracy
Maximum Output Current
66
| Danfoss Drives Oy © 2024.03
1
Value
9 ms
5 ms
See
Figure
47.
C
[A]
10
C
DC current
Value
10 V
-3...+3% of nominal voltage
10 mA
13 mA
2 kV
Value
24 V
-15...+20%
200 mA
AJ389643111587en-000101 / 172F6361A