Omron CJ2 CPU UNIT SOFTWARE User Manual page 612

Cj2 cpu unit software
Hide thumbs Also See for CJ2 CPU UNIT SOFTWARE:
Table of Contents

Advertisement

Appendices
Address
Name
Words
Bits
A326
A326.05
Pulse Output 2
No-origin Flag
A326.06
Pulse Output 2
At-origin Flag
A326.07
Pulse Output 2
Output Stopped
Error Flag
A326.08
Pulse Output 2
Interrupt Feed-
ing In-progress
Flag
A326.09
Pulse Output 2
Interrupt Feed-
ing Error Flag
A327
A327.00
Pulse Output 3
Pulse Output
Status Flag
A-128
Function
ON when the origin has not been determined for pulse output 2
and goes OFF when the origin has been determined.
OFF: Origin established, ON: Origin not established
ON when the PV of pulse output 2 matches the origin (0).
OFF: Not stopped at origin, ON: Stopped at origin
ON when an error occurred while outputting pulses in the pulse
output 2 origin search function. The Pulse Output 2 Output Stop
Error Code will be written to A438.
0: No error, ON: Stop error
These flags are turned ON when an interrupt input is received
after output from pulse outputs 2 to 3 is started with the
IFEED(892) instruction.
OFF: Interrupt feeding not in progress.
ON: Interrupt feeding in progress.
This flag will turn ON if an overflow or underflow occurs when an
interrupt input is received, or when the specified number of pulses
is moved, after output from pulse outputs 2 is started with the
IFEED(892) instruction.
OFF: Overflow/underflow or specified number of pulses has been
moved.
ON: No error.
This flag will be ON when pulses are being output from pulse out-
put 3 according to an ORG(889), ACC(888), PLS2(887), or
IFEED(892) instruction and the output frequency is being
changed in steps (accelerating or decelerating).
OFF: Constant speed, ON: Accelerating/decelerating
Status
Write timing/
Status at
after mode
Related flags, set-
startup
change
tings
Turned ON
Turned
Refreshed each
when oper-
ON when
cycle during over-
ation starts.
power is
seeing process.
turned
ON.
Cleared
Cleared
Refreshed each
cycle during over-
seeing process.
Cleared
Cleared
• Cleared when an
origin search is
started.
• Refreshed when
a fatal pulse out-
put error occurs
during an origin
search.
• Refreshed when
the limit input sig-
nal for pulse out-
put is set to be
always enabled in
the PLC Setup
and pulse output
is stopped due to
the limit input.
• Cleared when
both limit inputs
are disabled and
a fatal pulse out-
put error code is
stored.
Cleared
Cleared
• Cleared during
overseeing pro-
cessing after
completing inter-
rupt feeding.
• Refreshed when
interrupt input is
received after
starting pulse out-
put with
IFEED(892)
instruction.
Cleared
Cleared
• Cleared when
IFEED(892)
instruction pro-
cessing is
started.
• Turned ON if an
overflow or under-
flow occurs when
an interrupt input
is received, or if
an overflow or
underflow occurs
while the speci-
fied number of
pulses is being
moved, after
operation is
started with the
IFEED(892)
instruction with
the origin defined.
Cleared
Cleared
Refreshed each
cycle during over-
seeing process.
CJ2 CPU Unit Software User's Manual