Features • Even more program memory and data memory. • Superior high-speed control performance: LOAD instructions execute in 16 ns, SINE instructions in 0.59 μs. • Maximum throughputs with High-speed interrupt function • Efficient debugging through highly improved Data tracing •...
International Standards • The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz Vibration Resistance Acceleration of 9.8 m/s for 100 min in X, Y, and Z directions (10 sweeps of 10 min each = 100 min total) Conforms to JIS C60068-2-27.
DM Area * Bits in the EM Area can be addressed either by bit or by word. These bits cannot be addressed by CPU Bus Units, Special I/O Units, PTs, and Support Software that do not specifically support the CJ2 CPU Units.
Page 5
Interrupt tasks: 256 Number of Tasks (Interrupt tasks can be defined as cyclic tasks to create extra cyclic tasks. Therefore, the total number of cyclic tasks is actually 384 max.) • Local symbols: Can be used only within a single task in the PLC.
The response time can be decreased to enable detecting shorter input pulses. Basic I/O All of the outputs on Basic I/O Units can be turned OFF when an error occurs in RUN or Units Load OFF Function MONITOR mode.
Page 7
Serial Gateway This gateway enables receiving and automatically converting FINS to the CompoWay/F. Tasks can be executed at a specified interval (minimum of 0.2 ms or 0.1 ms *, Unit: 0.1 ms). Scheduled Interrupts * When High-speed interrupt function is used.
Page 8
This function detects an error when the same unit number is set for two or more Units, the Unit/Rack Number same word is allocated to two or more Basic I/O Units, or the same rack number is set for two Duplication Error or more Racks.
Note: User programs that use functions of CJ2H CPU Units with unit version 1.2 or later cannot be used with CJ2H CPU Units with unit version 1.1 or earlier. If an attempt is made to transfer a program that uses any of these functions from the CX-Programmer to a CPU Unit with unit version 1.1 or earlier , an error will be displayed and it will not be possible to download to the CPU Unit.
Page 10
*4. A Programming Console cannot be used with a CJ2H CPU Unit. Device Type Setting The unit version does not affect the setting made for the device type on the CX-Programmer. Select the device type as shown in the following table regardless of the unit version of the CPU Unit.
− Connector hood Protection earth Note: Do not use the 5-V power from pin 6 of the RS-232C port on the CPU Unit for anything but the NT-AL001-E Link Adapter. The external device or the CPU Unit may be damaged.
Page 12
CJ2H-CPU6@ Dimensions (Unit: mm) CJ2H CPU Unit CJ2H-CPU6@ 66.2 48.8 74.5...
Also refer to the Hardware User’s Manual (W472) CJ2H-CPU6@-EIP CJ2H-CPU6@ CS1G/H-CPU@@H CS1G/H-CPU@@-V1 CS/CJ/NSJ-series Describes each programming instruction in detail. W474 CJ1G/H-CPU@@H Instructions Reference Information on instructions Also refer to the Software User’s Manual (W473) when you CJ1G-CPU@@ Manual do programming. CJ1M-CPU@@ NSJ@-@@@@(B)-G5D NSJ@-@@@@(B)-M3D CJ2H-CPU6@-EIP CJ2H-CPU6@ CS1G/H-CPU@@H CS1G/H-CPU@@-V1...
Page 14
PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.
Need help?
Do you have a question about the CJ2H-CPU64 and is the answer not in the manual?
Questions and answers