A444
---
Pulse Output 0
Stop Error Code
A445
---
Pulse Output 1
Stop Error Code
A446
A446.00
Number of Times
to
Protection Has
A446.07
Been Disabled
A450
---
CIO Area Desig-
nation
A451
---
Word Area Des-
ignation
A452
---
Holding Area
Designation
CJ2 CPU Unit Software User's Manual
Function
If a Pulse Output Stop Error occurs for pulse output 0, the error
code is written to this word.
If a Pulse Output Stop Error occurs for pulse output 1, the error
code is written to this word.
• Counts up each time protection disable fails (i.e., due to the
protection disable password being input incorrectly).
• Displays the total number of times that protection was disabled
for UM protection and task protection.
• The counter stops counting when it reaches 255 (decimal).
• When all protection has been disabled, the counter will be set
to 00 hex.
This word stores a fixed code that is used to specify the area
when an address is specified as a parameter for a function block
instead of an input-output variable (VER_IN_OUT). This code is
used only by the OMRON FB Library. Do not change the contents
of this word.
This word stores a fixed code that is used to specify the area
when an address is specified as a parameter for a function block
instead of an input-output variable (VER_IN_OUT). This code is
used only by the OMRON FB Library. Do not change the contents
of this word.
This word stores a fixed code that is used to specify the area
when an address is specified as a parameter for a function block
instead of an input-output variable (VER_IN_OUT). This code is
used only by the OMRON FB Library. Do not change the contents
of this word.
Appendices
Status
Write timing/
Status at
after mode
Related flags, set-
startup
change
tings
Retained
Cleared
• Cleared when an
origin search is
started.
• Refreshed when
a fatal pulse out-
put error occurs
during an origin
search.
• Refreshed when
the limit input sig-
nal for pulse out-
put is set to be
always enabled in
the PLC Setup
and pulse output
is stopped due to
the limit input.
• Cleared when
both limit inputs
are disabled and
a fatal pulse out-
put error code is
stored.
Retained
Cleared
• Cleared when an
origin search is
started.
• Refreshed when
a fatal pulse out-
put error occurs
during an origin
search.
• Refreshed when
the limit input sig-
nal for pulse out-
put is set to be
always enabled in
the PLC Setup
and pulse output
is stopped due to
the limit input.
• Cleared when
both limit inputs
are disabled and
a fatal pulse out-
put error code is
stored.
---
---
---
Fixed value
Fixed
---
is set.
value is
set.
Fixed value
Fixed
---
is set.
value is
set.
Fixed value
Fixed
---
is set.
value is
set.
A-143